WARNING: USE ONLY CERAMIC GLASS 5mm
THICK. ABUSE SUCH AS STRIKING, SLAMMING AND USE OF SUBSTITUTE MATERIALS SHOULD BE AVOIDED.
FIRE SAFETY
To provide reasonable fire safety, the following should be given serious consideration:
1.The installation of smoke detectors.
2.A conveniently located Class A fire extin- guisher to contend with small fires resulting from burning embers.
3.A practiced evacuation plan.
4.A plan to deal with a chimney fire as follows:
IN THE EVENT OF A CHIMNEY FIRE
(a)Notify the fire department.
(b)Prepare occupants for immediate evacuation
(c)Close all openings into the stove.
(d)While awaiting fire department watch for igni- tion to adjacent combustibles from over heated stove pipe or hot embers or sparks from the chimney.
LEPRECHAUN 90 O.S.A.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: |
|
SIDE WALL TO STOVE | .20 INCHES - 510 mm |
BACK WALL TO CHIMNEY CONNECTOR | 18 INCHES - 460mm |
BACK WALL TO STOVE TOP & REAR EXIT | 141/2” INCHES - 370mm |
CEILING TO HORIZONTAL CONNECTOR | 18 INCHES - 460mm |
CORNER | 13 INCHES - 330mm |
MANTLE CLEARANCE | 25 INCHES - 635mm |
SIDE TRIM | 14 INCHES - 355mm |
FLOOR PROTECTION
When installing this heater on a combustible floor, a floor protector consisting of a layer of