7.The chimney system shall comply with the standard for Chimney’s
8.Any openings in a chimney guard if used must not permit the entrance of a 3/4” (19mm) diameter rod.
9.CAUTION: THE STRUCTURAL INTEGRI TY OF THE MOBILE HOME ROOF, FLOOR, WALLS AND CEILING MUST BE MAINTAINED.
10.Check any other local building code as other local codes may apply.
11.WARNING: DO NOT INSTALL IN A SLEEPING ROOM
Note: Listed factory built chimney connectors including elbows are acceptable for use in Mobile Home Installation’s.
WALL PROTECTORS
Materials and products listed for the purpose of reducing clearance to combustibles shall be installed in accordance with the conditions of the listing and the clearances may be reduced by the percentage reduction as stated in the wall shield manufacturer’s instructions.
For clearance reduction systems using an air space between the combustible wall and the wall protector, adequate air circulation shall be provided by one of the following methods.
1.Adequate air circulation may be provided by leaving all edges of the wall protector open with at least a 1” 25mm air gap.
2.If the wall protector is mounted on a single flat wall away from corners, adequate air cir- culation may be provided by leaving bottom and top edges open with at least a 1” 25mm air gap.
3.Wall protectors that cover two walls in a cor- ner shall be open at the bottom and top edges with at least a 1” 25mm air gap.