Input Power for use with JandyAquaLink® RS:

Wire the AquaRite® DIRECTLY to 120/240VAC power (not through timer or re- lay).

JANDY

AQUALINK RS

(120 VAC)

AQUA RITE

AQUA RITE

(240 VAC)

(120 VAC)

SUBPANEL

NEUTRAL

GROUND

GND

PCB

BONDING

LOOP

GND

PCB

BONDING

LOOP

Optional Jandy AquaLink RS:

The Jandy AquaLink RS and Aqua Rite use a 4 wire connection to communicate and can be wired up to 500' apart. Any outdoor rated 4 conductor cable can be used. Locate appropriate screw terminals on the circuit board according to the diagram below (screw terminals are removable to aid in installation). IMPORTANT: Attach wires to like numbered screw terminal on both the Aqua Rite and AquaLink RS as shown in the diagram below. Refer to Jandy's instructions for proper wire connec- tion to the AquaLink RS.

4

GREEN

 

 

3

YELLOW

 

 

2

BLACK

Jumper Installed

Jumper Removed

1

RED

For Master

For Slave(s)

 

 

(Factory Default)

 

 

 

Additional

Aqua Rite(s)

(if required)

Jandy

Jandy

Aqua Rite

Aqua Rite

In-House

Controller

Power Center

(Master)

(Slave)

Notes:

1.Never put more than 2 wires on a single terminal. Use the optional Jandy multi- plex PCB if necessary.

2.There must be only 1 "master" unit. All other Aqua Rite units must be config- ured as "slaves".

12

Page 15
Image 15
Waterpik Technologies Electronic Chlorine Generator manual Input Power for use with JandyAquaLink RS