PURGING

After the piping and meter have been checked completely, purge the system of air. Do not bleed the air inside the furnace. Be sure to relight all the gas pilots on other appliances.

PURGING

After the piping has been checked, all piping and appliances receiving gas through the meter shall be fully purged. A suggested method for purging th gas line to the burner is to disconnect the pilot line at the outlet o the pilot valve. Under no circumstances shall th line be purged into the combustion chamber.

After th e gad line to the conversion burner has been fully purged and the pilot line reconnected, the gas supply at other pilot burners located on other gas appliances which were extinguished as the result of interrupted service shall be reignited.

LENGTH OF STANDARD PIPE THREADS inches (mm)

 

EFFECTIVE

OVERALL

PIPE SIZE

LENGTH

LENGTH

 

OF THREAD

OF THREAD

3/8 (9.525)

3/8 (9.525)

9/16 (14.29)

1/2 (12.7)

1/2

(12.7)

3/4 (19.05)

3/4 (19.05)

1/2 - 9/16 (14.29)

13/16 (20.64)

1 (25.4)

9/16

(14.29)

1 (25.4)

PIPE CAPACITY TABLE

 

 

 

Nominal Diameter of Pipe in Inches

 

 

 

 

 

3/4 (19.05)

 

1(25.4)

 

1-1/4 (31.75)

 

1-1/2 (38.1)

 

2 (50.8)

Length

 

 

 

 

 

 

 

 

 

 

of Pipe

 

 

Capacity - Cu, Ft. Per Hr. with a 0.6

 

 

 

in Feet

Sp. Gr. Gas and Press. Drop of 0.3 In. (74.72 Pa) Water Col.

15 (4.572)

172

 

345

 

750

 

 

 

 

 

30 (9.144)

120

 

241

 

535

 

850

 

 

 

45 (13.72)

99

 

199

 

435

 

700

 

 

 

60 (18.29)

86

 

173

 

380

 

610

 

 

 

75 (22.86)

77

 

155

 

345

 

545

 

 

 

105

(32)

65

 

131

 

285

 

450

 

920

120

(36.58)

 

 

120

 

270

 

420

 

860

180

(54.86)

 

 

100

 

225

 

350

 

720

 

 

 

 

 

FIGURE 8

To convert the figures given above to capacities for another gas of different specific gravity, multiply the tabular values by the multiplier shown below.

MULTIPLIER FOR VARIOUS

SPECIFIC GRAVITIES

SPECIFIC

 

SPECIFIC

 

GRAVITY

MULTIPLIER

GRAVITY

MULTIPLIER

.35

1.31

1.00

.775

.40

1.23

1.10

.740

.45

1.16

1.20

.707

.50

1.10

1.30

.680

.55

1.04

1.40

.655

.60

1.00

1.50

.633

.65

.962

1.60

.612

.70

.926

1.70

.594

.75

.895

1.80

.577

.80

.867

1.90

.565

.90

.817

2.10

.535

 

 

 

 

8