OPERATING INSTRUCTIONS

Lighting

Summary lighting instructions are on the control panel.

mDANGER

Failure to open lid while igniting the barbecue, or not waiting 5 minutes to allow the gas to clear if the barbecue does not light, may result in an explosive flame-up which can cause serious bodily injury or death.

Crossover Ignition System

Note - The Crossover Ignition System ignites the Front burner with a spark from the igniter electrode inside the Gas Catcher Ignition Chamber. You generate the energy for the spark by pushing the Crossover Ignition Button until it clicks.

mWARNING: Check hose before each use of barbecue for nicks, cracking, abrasions or cuts. If the hose is found to be damaged in any way, do not use the barbecue. Replace using only Weber authorized replacement manifold assembly. Call your dealer for the necessary parts.

mWARNING: The burner control knobs must be in the

OFF position before turning on the LP tank valve. If they are not in the OFF position, when you turn on the LP tank valve, the excess flow control will activate, limiting the flow of gas from the LP tank. If this should occur, turn OFF the LP tank valve and burner control knobs and start over.

mDANGER

When the excess flow control is activated, a small amount of gas is still flowing to the burners. After turning OFF the tank and burner control knobs, wait at least 5 minutes for the gas to clear before attempting to light the barbecue. Failure to do so may result in an explosive flame-up which can cause serious bodily injury or death.

4)Turn the tank on by turning the tank valve counterclockwise.

mWARNING: Do not lean over open barbecue. Keep your face and body at least one foot away from the matchlight hole when lighting the barbecue.

1

7

5

6

Crossover Ignition System

3

8

4

2

5)Push Front burner control knob down and turn to START/HI.

6)Push the Crossover Ignition Button several times, so it clicks each time.

7)Check that the burner is lit through the matchlight hole on the front of the cooking box.

mWARNING: If the burner does not light, turn the

Front burner control knob to OFF and wait 5 minutes to let the gas clear before you try again or try to light with a match.

8)After the FRONT burner is lit you can turn on the other burners.

Note - Always light the FRONT burner first. The other burners ignite from the FRONT burner.

Figure 1

1)Open the lid. Figure 1.

2)Check that the fuel scale reads more than “E”. Note - E = empty; F = full.

3)Make sure all burner control knobs are turned OFF. (Push each burner control knob down and turn clockwise.)

To Extinguish

Turn gas supply OFF at the source, then push down and turn each burner control knob clockwise to OFF.