Step 15

Check for gas leaks

mDANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for leaks. This will result in a fire or explosion which can cause serious bodily injury or death and damage to property.

mWARNING: You should check for gas leaks every time you disconnect and reconnect a gas fitting.

Note - All factory made connections have been thoroughly checked for gas leaks. The burners have been flame tested. As a safety precaution you should recheck all fittings for leaks before using your Weber Gas Barbecue. Shipping and handling may have loosened or damaged a gas fitting.

mWARNING: Perform these leak checks even if your barbecue was dealer or store assembled.

You will need: soap and water solution and a rag or brush to apply it.

Make sure side burner is OFF. Remove valve control knob and screws. Remove porcelain top. Figure 22.

Check:

a)Gas supply line to manifold connection. Figure 24 (a).

b)Manifold to side burner hose connection. Figure 24 (b).

mWARNING: If there is a leak at connection (a) or (b), retighten the fitting with a wrench and recheck for leaks with soap and water solution.

If a leak persists after retightening the fitting, turn OFF the gas. DO NOT OPERATE THE BARBECUE.

Contact your dealer.

c)Side burner hose to side burner connection. Figure 24 (c).

d)Valves to manifold connections. Figure 24 (d).

mWARNING: If there is a leak at connections (c) or (d), turn OFF the gas. DO NOT OPERATE THE BARBECUE.

Contact your dealer.

e)Barbecue gas supply line to natural gas supply connection. Figure 24 (e).

mWARNING: If there is a leak at connection (e), turn OFF the gas. DO NOT OPERATE THE BARBECUE.

Contact your installer.

When leak checks are complete, turn gas supply OFF and rinse connections with water.

f)Reinstall the side burner cover. Figure 22.

(a)

(b)

Figure 22

To perform leak checks: Turn ON gas supply at the source. Figure 23.

Gas supply shut off at the house

(c)

Figure 23

mWARNING: Do not ignite burners while leak checking.

Check for leaks by wetting the connections with the soap

(e)

(d)

 

and water solution and watching for bubbles. If bubbles

 

 

form or if a bubble grows there is a leak.

 

 

 

 

Note - Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks.

Figure 24

22