CHECK FOR GAS LEAKS

Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form or if a bubble grows there is a leak.

Note - Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks.

WARNING: Do not ignite burners when leak checking.

a)

c)

Manifold

To regulator

Summit 475

d)

Figure 24

 

 

Manifold

b)

a)

c)

Manifold

To regulator

d)

Summit 675

Figure 24

Manifold

Check:

a)Left valves to manifold connection. Figure 24 (a).

b)Center valves to manifold connection. Figure 24 (b). (For Summit 675 only.)

c)Right valves to manifold connection. Figure 24 (c).

d)Gas line to manifold connection. Figure 24 (d)

e)Leak check all gas supply connections.

WARNING: If there is a leak at connection 24 (d), turn OFF the gas and retighten the fitting with a wrench and recheck for leaks with soap and water solution.

If a leak persists after retightening the fitting, turn OFF the gas. DO NOT OPERATE THE BARBECUE. Contact your dealer.

WARNING: If there is a leak at connections

24 (a), 24 (b), or 24 (c) turn OFF the gas. Do not operate the barbecue. Contact your dealer.

When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.