BUILT-IN CONSTRUCTION GENERAL INFORMATION

WARNING

A Weber-Stephen Products Co. insulated sleeve must be used for any built-in installation.

LOCATING YOUR BARBECUE

When determining a suitable location for your barbecue installation, give attention to concerns such as exposure to wind, proximity to traffic paths, and keeping any gas supply lines as short as possible. Never locate the Weber Gas Barbecue in a garage, breezeway, shed, under an unprotected overhang, or other enclosed area. Locate the barbecue and structure so there is enough room to safely evacuate the area in case of a fire.

CLEARANCE FROM NON-COMBUSTIBLE SURFACES OR STRUCTURES

Warning: Clearance from the outside walls of the sides and back of the insulated sleeve must be a minimum of 6 inches from a non-combustible surface. Measure from the outside wall of the insulated surface to the non-combustible surface . Figure 1. Refer to “Install Gas Supply” on page 2 before starting installation.

NON- COMBUSTIBLE SURFACE

CLEARANCE FROM COMBUSTIBLE SURFACES OR STRUCTURES

Warning: Clearance from the outside walls of the sides and back of the insulated sleeve must be a minimum of 24 inches from a combustible surface. Measure from the outside wall of the insulated surface to the combustible surface. Figure 2. Refer to “Install Gas Supply” on page 2 before starting installation.

COMBUSTIBLE SURFACE

24 inches

Insulated sleeve

Countertop

Figure 2

WARNING: All countertop finished surfaces must be constructed of a noncombustible material.

6 inches

Insulated sleeve

Countertop

Figure 1

WARNING: All countertop finished surfaces must be constructed of a noncombustible material.