GAS SUPPLY

TYPICAL 20 LP PROPANE GAS SUPPLY INSTALLATION

The remote tank enclosure kit provided with your Weber Built-In grill shall be used for installations using a 20 lb LP cylinder, mounted in an “island” structure.

The remote tank enclosure shall house the included hose and regulator assembly and gas connections, the tank bracket and the fuel scale for connecting a remote mounted LP cylinder to the Summit® Built-In gas grill. The hose and regulator is listed as a required part of the CSA listed Summit® Built-In gas grill.

A properly installed tank enclosure meets the requirements for venting, tank retention and separation of the LP cylinder from a heat source as outlined in the ANSI Standard for Outdoor Cooking Gas Appliances, Z21.58/CSA 1.6 for LP enclosures.

You need to hire a licensed contractor or licensed plumber and they need to follow the requirements described in the ANSI Standard for Outdoor Cooking Gas Appliances, Z21.58/CSA 1.6 for LP enclosures.

The requirements described in the Standard for Outdoor Cooking Gas Appliances, Z21.58/CSA 1.6. are as follows;

A remote enclosure for an LP gas cylinder shall be ventilated by openings at both the upper and lower levels of the cylinder. This shall be accomplished by one of the following:

A)One side of the remote LP cylinder enclosure shall be completely open; or

B)If the remote LP cylinder enclosure is designed to have four sides, a top and a bottom, ventilation is required for the remote LP cylinder enclosure;

a)There should be at least two ventilation openings, (a hole or group of holes, for the purpose of ventilation) in the sidewalls of the island structure. The openings should be located within 5 inches (127 mm) of the top of the enclosure. The ventilation openings should be equally sized and spaced at a minimum of 90 degrees, and be unobstructed. The openings shall have a total free open area of not less than 20 square inches. (This relates to 1 square inch of ventilation area, per pound of stored fuel capacity).

b)Ventilation openings (a hole or group of holes, for the purpose of ventilation) should be provided at floor level. The ventilation openings should have a total free area of not less than 10 square inches. (This relates to 1/2 square inch of ventilation area, per pound of stored fuel capacity). There should be at least two ventilation openings if the ventilation openings at floor level are in the sidewall. The ventilation openings should be within 5 inches (127 mm) of the floor. The ventilation openings should be of equal size and be spaced at a minimum of 90 degrees, and should be unobstructed.

c)The minimum size of the ventilation hole(s) should not be less than 1/4 inch.

d)The ventilation openings in the sidewalls should not allow venting into the empty or “hollow” area of the “island”. If a gas leak should occur or the LP cylinder should vent in the LP cylinder enclosure, the gas should not be allowed to vent or migrate into the empty or “hollow” area of the “island”. Ventilation openings in the sidewalls of the enclosure should only communicate with the outside of the “island” structure, so that the gas can dissipate outside of the “island” structure.

C)If the remote LP cylinder enclosure has four sides, a top and a bottom, and is intended for installation in a built-in “island” enclosure;

a)At least one ventilation opening (a hole or group of holes, for the purpose of ventilation) needs to be on one side of the enclosure that communicates with the outside of the “island” structure. If a gas leak should occur or the LP cylinder should vent in the LP cylinder enclosure, the gas should not be allowed to vent or migrate into the empty or “hollow” area of the “island”. Ventilation openings should only communicate with the outside of the “island” structure, so that

the gas can dissipate outside of the “island” structure. The ventilation opening should be located within 5 inches (127 mm) of the top of the enclosure, and should have a total free area of 20 square inches. (This relates to 1 square inch of ventilation area, per pound of stored fuel).

b)At least one ventilation opening (a hole or group of holes, for the purpose of ventilation) needs to be on one side of the enclosure that communicates with the outside of the “island” structure, at the bottom. If a gas leak should occur or the LP cylinder should vent in the LP cylinder enclosure, the gas should not be allowed to vent or migrate into the empty or “hollow” area of the “island”. Ventilation openings should only communicate with the outside of the “island” structure, so that the gas can dissipate outside of the “island” structure. The ventilation opening should be located within 5 inches (127 mm) of the bottom of the enclosure, and should have a total free area of 10 square inches. (This relates to 1/4 square inch of ventilation area, per pound of stored fuel).

c)The minimum size of the ventilation hole(s) should not be less than 1/4 inch (6.35 mm).

D)The remote LP cylinder enclosure should be constructed with non-combustible materials. The remote LP cylinder enclosure should isolate the LP cylinder from the burner compartment, so that it provides shielding from radiation, be a flame barrier and provide protection from foreign material such as hot drippings.

E)There should be a minimum of 2 inches (50.8 mm) between the ground and the floor of the remote LP cylinder enclosure.

F)The LP cylinder valve should be readily accessible for hand operation. A door on the remote LP cylinder enclosure to gain access to the LP cylinder valve is acceptable, provided it is non-locking and can be opened without the use of tools.

mDANGER

Use of any hose and regulator assembly other than that provided or recommended by Weber-Stephen Products LLC could be dangerous, and may not provide adequate gas supply to the Summit® Built-In gas grill, and could result in a fire or an explosion causing serious bodily injury or death, and damage to property.

mDANGER

Failure to build a remote LP cylinder enclosure for a single 20 lb cylinder only, following the requirements for ventilation, cylinder retention and separation of the LP cylinder from a heat source, listed in the ANSI Standard for Outdoor Cooking Gas Appliances, ANSI Z21.58 CSA 1.6, could be dangerous, and could result in a fire or an explosion causing serious bodily injury or death and damage to property.

If you do not follow the DANGER statements exactly, the Warranty on the Summit® Built- In gas grill will be voided.

www.weber.com® 25

Page 129
Image 129
Weber 660- LP, Weber manual Typical 20 LP Propane GAS Supply Installation

660- LP, Weber specifications

The Weber Weber 660-LP is a premier gas grill that embodies quality engineering and innovative design, catering to both beginners and seasoned grilling enthusiasts. This grill stands out in the market for its combination of performance, versatility, and user-friendly features, making it a substantial choice for outdoor cooking.

One of the defining features of the Weber 660-LP is its high BTU output. With a powerful main burner system, it provides ample heat distribution across the cooking surface, ensuring that food is cooked evenly and efficiently. The grill boasts a total cooking area that accommodates up to 20 burgers at once, making it ideal for gatherings, barbecues, and family meals.

Equipped with innovative grilling technology, the Weber 660-LP incorporates the “GS4 Grilling System.” This unique system enhances the grilling experience by integrating four key features: a powerful ignition system for reliable startup, improved burners for consistent heat distribution, a grease management system for easy clean-up, and a flavorizer bar design that enhances flavor while preventing flare-ups.

The construction of the Weber 660-LP is another point of admiration. Made from high-quality stainless steel, the grill is built to withstand the elements, ensuring durability and longevity. Its spacious side tables offer additional prep space, while integrated hooks provide convenient storage for grilling tools.

Additionally, the 660-LP features open cart design for easy access to the propane tank and includes built-in hooks for tool organization. This thoughtful design simplifies the grilling process, allowing users to focus on the cooking rather than the setup and storage.

Another highlight of the Weber 660-LP is its efficient ignition system, which uses a simple push button to ignite the burners reliably. This feature reduces frustration and enhances the overall grilling experience, making it accessible for grillers of all skill levels.

With its impressive array of features and technologies, the Weber Weber 660-LP gas grill delivers exceptional performance, making it a must-have for anyone serious about outdoor cooking. Whether you’re searing steaks, grilling vegetables, or hosting a backyard party, this grill ensures delicious results every time, transforming your grilling sessions into memorable culinary experiences.