GOLD CGs
13b Ratings
|
|
|
|
|
|
|
| DOE |
| ||
|
|
|
|
|
|
|
|
|
|
| (Note 5) |
|
|
|
|
|
|
|
|
|
|
| |
Table 7 Boiler ratings |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
Boiler |
| DOE | Net | Boiler |
| DOE | Vent | ||||
model | Heating |
|
|
|
| I=B=R | water |
| Seasonal | size | |
Input | Output | Input | Output |
| |||||||
number | capacity | ratings | content |
| efficiency |
| |||||
|
| (Btuh) | (Btuh) | (Btuh) | (Btuh) | (Btuh) | (Btuh) | (gallons) |
| (% AFUE) |
|
|
|
|
|
|
|
|
|
|
|
|
|
(Note 1) |
| (Note 2) |
|
|
|
| (Note 3) |
|
| (Note 5) | (Note 4) |
|
|
|
|
|
|
|
|
|
|
|
|
| 57,000 | 67,000 | 57,300 | 60,300 | 51,600 | 50,000 | 1.5 |
| 85.3 | 3" | |
(Note 5) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 85,000 | 100,000 | 85,000 | 90,000 | 76,500 | 74,000 | 2.1 |
| 84.6 | 3" | |
|
|
|
|
|
|
|
|
|
|
|
|
| 112,000 | 133,000 | 112,400 | 119,000 | 100,600 | 97,000 | 2.7 |
| 84.0 | 3" | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 140,000 | 167,000 | 140,300 | 150,300 | 126,300 | 122,000 | 3.3 |
| 83.4 | 3" |
|
|
|
|
|
|
|
|
|
|
|
|
| 1. | Add “PIN” for natural gas boiler - “PIL” for propane gas boiler. |
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
| |
| 2. | Based on standard test procedures prescribed by the United States Department of Energy. |
| ||||||||
|
|
|
|
|
|
|
|
|
|
| |
| 3. | Net I=B=R ratings are based on net installed radiation of sufficient quantity for the requirements of the building | |||||||||
|
| and nothing need be added for normal piping and pickup. Ratings are based on a piping and pickup allowance | |||||||||
Notes |
| of 1.15. An additional allowance should be made for unusual piping and pickup loads. |
|
| |||||||
|
|
|
|
|
|
|
|
|
|
| |
| 4. | CGs boilers require special venting, consistent with Category III or IV boiler. Use only the vent materials and | |||||||||
|
| methods specified in CGs vent supplements. CGs boilers may be | |||||||||
|
| as specified in the direct vent supplements. |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| |
| 5. | As an Energy Star Partner, | |||||||||
|
| energy efficiency. |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
CGs boilers for residential radiant panel systems, converted gravity heating systems or other low water tempera- ture applications should be installed with balancing valves and bypass piping equal to the supply and return size to avoid excessive flue gas condensation due to lower operating water temperatures. For alternate piping, contact your
Part number
63