Weil-McLain 80, 230, 310, 105 Install water piping continued, Zoning with zone valves, DHW piping

Models: 155 105 310 230 80

1 44
Download 44 pages 43.26 Kb
Page 15
Image 15
Zoning with zone valves

3Zone valve zoning plus optionalDHW pipingManual background GAS-FIRED WATER BOILER — Boiler Manual

Install water piping (continued)

Zoning with zone valves

Figure 7

Zone valve zoning plus optional

1.

Connect boiler to system as shown in Figure 7 when

 

DHW piping

 

 

 

zone valve zoning. The primary/secondary piping

 

 

 

shown ensures the boiler loop will have sufficient

 

 

 

flow. It also avoids applying the high head of the

 

 

 

boiler circulator to the zone valves.

 

 

2.

When using a closed-type expansion tank, connect

 

 

 

the expansion tank and make-up water piping as

 

 

 

shown in Figure 4, page 13.

 

 

3.

Connect DHW (domestic hot water) piping to indirect

 

 

 

storage water heater as shown.

 

 

 

 

The

PhDControl Module turns off

 

 

 

 

 

 

space heating during DHW heating. The boiler circulator will turn off, preventing hot water from circulating to the system. The flow/check valve shown on the boiler outlet piping prevents gravity circulation in the boiler loop during DHW heating.

4.Controlling the system circulator

a.To cycle the system circulator from the Ultra PhD control module, add a circulator relay wired to the boiler circulator terminals as shown in the Ultra Control Supplement.

NOTE 1: To ensure adequate flow rate through the boiler, use the following pipe size on all boiler loop piping (connecting boiler to and from the primary/secondary connection, item 21): Ultra-80 or Ultra-105 – 1" or larger.

Ultra-155 or -230 – 1¼" or larger. Ultra-310 – 1½" or larger.

Use at least the minimum piping size above and pipe the boiler using only primary/ secondary piping as shown. Failure to follow these guidelines could result in system problems.

Legend

Figure 7

1Ultra boiler

2Indirect water heater (DHW), if used

3Boiler relief valve (see page 12 for piping details)

4Relief valve discharge piping (see page 12 for details)

5DHW circulator (see page 14 for suggested sizing)

6Isolation valves

7System circulator

8Diaphragm (or bladder) type expansion tank (see page 12 for piping of closed-type expansion tank, if used)

9Air separator [with automatic air vent only on systems using diaphragm (or bladder) type expansion tank]

10Flow/check valves (with weighted seats to prevent gravity circulation)

11Purge/drain valves

12Boiler circulator

13Zone valves, typical

20Make-up water supply

21Primary/secondary connection

Part number 550-101-233/0903

15

Page 15
Image 15
Weil-McLain 80 Install water piping continued, Zoning with zone valves, GAS-FIRED WATER BOILER - Boiler Manual, DHW piping