EG-75, EGH-85, EGH-95,

UserísInformationManual

Lighting instructions

EG-75, EGH-85, EGH-95,

Standing pilot

PFG-6, PFG-7

Gas valve Robertshaw 7000ERHC

FORYOUR SAFETY READ BEFORE LIGHTING

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot, which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.Before LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. See below.

C.Use only your hand to depress or turn the gas control knob. Never use tools. If the selector arm will not depress or move by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control, which has been under water.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

OPERATING INSTRUCTIONS

1.Stop! Read the safety information above on this label.

2.Set the thermostat to lowest setting.

3.Turn off all electrical power to the appliance.

4.Depress gas control knob slightly and turn clockwise PFG-6, PFG-7 to OFF.

Gas control knob

(shown in ON position)

•Gas valve — Robertshaw 7000ERHC Position indicator

59205

Note: Gas control knob cannot be turned to OFF unless knob is depressed slightly. Do not force.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step.

6. Remove access panel located above burners.

7. Find pilot — follow metal tube from gas control. The pilot is between two burners behind the access panel.

8.Turn gas control knob counterclockwiseOPERATING INSTRUCTIONSto PILOT.

9.Depress gas control knob and hold. Immediately light the pilot with a match. Continue to hold gas control knob in for about one (1) minute after the pilot is lit.

If pilot can be lit without depressing gas control knob,

turn gas knob clockwiseManual backgroundto OFF and call your ser- vice technician or gas supplier.

10.Release gas control knob. Pilot should remain lit. If pilot goes out, repeat steps 4 through 10.

If gas control knob stays depressed after release, stop and immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the

gas control knob clockwise to OFF and call your service technician or gas supplier.

11.Replace access panel.

12.Turn gas control knob counterclockwiseManual backgroundto ON.

13.Turn on all electric power to the appliance.

14.Set thermostat to desired setting.

15.Replace front panel.

TOTURN OFF GASTOTHE APPLIANCE

1.Set the thermostat to lowest setting.

2.Turn off all electric power to the appliance if service is to be performed.

3.Remove front panel.

4.Depress gas control knob slightly and turn clockwise Manual background to OFF.

5.Replace front panel.

Part Number 550-110-592/1000