UserísInformationManual
User maintenance procedures
Boiler must be serviced & maintained
The boiler should be inspected and started annually, at the beginning of the heating season, only by a qualified service technician. In addition, the maintenance and care of the boiler designated on page 6 and explained on the following pages must be performed to assure maximum boiler efficiency and reliability. Failure to service and maintain the boiler and system could result in equipment failure, causing possible severe personal injury, death or substantial property damage.
The following information provides detailed instructions for completing the maintenance items listed in the maintenance schedule, page 6. In addition to this maintenance, the boiler must be serviced and started up at the beginning of each heating season by a qualified service technician.
Component information
CGa, CGi, CGs, EG, EGH, PEG &
Cuts off gas flow should flame rollout occur. See
Figure 1.
Do not attempt to place boiler in operation if rollout thermal fuse element cuts off gas flow. Immediately call a service technician. Failure to do so can cause severe personal injury, death or substantial property damage.
Figure 1
Rollout thermal fuse element
CGa, EG, EGH, PEG &
Cuts off gas flow should vent system become blocked.
See Figure 2.
Do not attempt to place boiler in operation if spill switch cuts off gas flow. Immediately call a service technician. Failure to do so can cause severe personal injury, death or substantial property damage.
Figure 2
Spill switch
59202
❏Check daily . . . . . . . . . . . . . . . . .
Boiler area
To prevent potential of severe personal injury, death or substantial property damage, eliminate all materials discussed below from the boiler vicinity. If found:
•Remove products immediately from the area. If they have been there for an extended period, call a qualified service technician to inspect the boiler and vent system for possible damage from acid corrosion.
•If products cannot be removed, immediately call a
qualified service technician to install an outside combustion air source for the boiler (if not already installed).
1.Combustible/flammable materials — Do not store combustible materials, gasoline or any other flammable vapors or liquids near the boiler. Remove immediately if found.
2.Air contaminants — See listing of contaminants on page 3.