Weil-McLain CGs, PEG EGH-85to EGH-125, PFG-6to PFG-8, Spark-ignitedpilot, Operating instructions

Models: CGi PFG PEG LGB CGs EGH

1 24
Download 24 pages 40.3 Kb
Page 20
Image 20
EGH-85 to EGH-125,

CGa,CGi,CGs,EG,EGH,LGB,PEG,PFGBoilers

Operating instructions

EGH-85 to EGH-125,

Spark-ignited pilot

PFG-6 to PFG-8

Gas valve Robertshaw 7000DERHC

FORYOUR SAFETY READ BEFORE LIGHTING

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.

B.Before OPERATING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. See below.

C.Use only your hand to turn the gas control knob. Never use tools. If the selector arm will not depress or move by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control, which has been under water.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

OPERATING INSTRUCTIONS

1.Stop! Read the safety information above on this label.

2.Set the thermostat to lowest setting.

3.When equipped with Effikal vent damper Model RVGP, place service switch in Hold

Damper Open position.

4.Turn off all electrical power to the appliance.

5.When equipped with Johnson Controls vent damper Model M35, manually rotate damper blade in direction of arrow to Open position indicated on damper assembly.

6. Turn gas control knob clockwise • Spark-ignited pilot to OFF.

7.When equipped with vent damper, verify damper blade is in full open position.

8.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step.

9. Turn gas control knob counterclockwise

to PILOT.

59205b

 

10.Turn on all electric power to the appliance.

11.When equipped with Effikal vent damper, place service switch in Automatic Operation position.

12.Set thermostat to desired setting.

13.If the appliance will not operate, follow the instructions "TO TURN OFF GAS TO APPLIANCE" below and call your service technician or gas supplier.

14.Replace front panel.

TOTURN OFF GASTOTHE APPLIANCE

Gas control knob

(shown in ON position)

Position indicator

1.

Set the thermostat to lowest setting.

3.

Remove front panel.

 

2.

Turn off all electric power to the appliance if service is to

4.

Turn gas control knob clockwise

to OFF.

 

be performed.

5.

Replace front panel.

 

 

 

 

20

Part Number 550-110-592/1000

Page 20