AGENCY LISTING INFORMATION

STD 4

E6070

E6070

This appliance conforms to NSF Standard 4 for sanitation only if installed in accordance with the supplied Installation Instructions and maintained according to the instructions in this manual.

This appliance is U Listed under UL File E6070 for 208V and 240V.

This appliance is V Listed under UL File E6070 for 208V and 240V .

INSTALLATION

NOTE: DO NOT discard the carton or other packing materials until you have inspected the appliance for hidden damage and tested it for proper operation.

Refer to SHIPPING DAMAGE CLAIM PROCEDURE on the inside front cover of this manual.

WARNING:

Risk of personal injury

Installation procedures must be performed by a qualified technician with full knowledge of all applicable electrical and plumbing codes. Failure can result in personal injury and property damage.

CAUTION:

ELECTRIC SHOCK

HAZARD

This appliance is equipped with a grounding system to protect you from electrical shock in the event of internal damage. DO NOT cut or remove the large ground prong on the plug. DO NOT twist any blade on the plug to fit an existing receptacle.

UNPACKING & INSPECTION

Carefully remove the appliance from the carton. Remove all protective plastic film, packing materials and accessories from the Appliance before connecting electrical power or otherwise performing any installation procedure.

Carefully read all instructions in this manual and the Installation Instruction Sheet packed with the appliance before starting any installation.

Read and understand all labels and diagrams attached to the appliance.

Carefully account for all components and accessories before discarding packing materials. Store all accessories in a convenient place for later use.

SETUP

Setup the appliance only on a firm, level surface. Verify local codes for requirements. Concrete, tile, terrazzo or metal surfaces are recommended.

Install provided 4" adjustable legs, one on each corner of the appliance, in the holes provided. Verify that the unit sits firmly ON ALL FOUR LEGS. With a spirit level, check that the appliance is level front-to-back and side-to-side. With the adjustable legs, adjust as required to level the appliance. All four legs must be adjusted to firmly contact the countertop in order to prevent tipping.

Refer to the Installation Instruction Sheet for required clearances. Maintain required clearances between the appliance and adjacent combustible surfaces.

Avoid storing flammable or combustible materials in, on or near the appliance.

ELECTRICAL

This appliance requires a properly grounded 30 amp 208 or 240 VAC single phase circuit and NEMA 6-30R receptacle.

4

Page 6
Image 6
Wells FT-18 operation manual Agency Listing Information, Installation