![](/images/new-backgrounds/1065464/6546417x1.webp)
OPERATING CONTROLS
Controls include a lighted POWER SWITCH and an amber REPLACE FILTER indicator light.
Press POWER SWITCH to ON anytime conveyor warmer is operating.
When power is first turned on, the REPLACE FILTER light will glow.
As the fan comes up to speed and air flow is established, the REPLACE FILTER light will go out.
If the REPLACE FILTER light does not go out, the filters must be replaced. However, the fan will continue to operate when the REPLACE FILTER light is lit.
FILTER REMOVAL AND INSTALLATION
Disconnect power from hood and conveyor warmer before servicing filters.
Remove screw from filter access panel on front (operator's) side of hood. Slide filter pack (high efficiency filter and charcoal filter) from filter chamber.
Slide new filter pack into filter chamber. Be sure airflow markings on both filters point "up".
Close access panel and reinstall screw.
IMPORTANT:
Filters are disposable. Never attempt to wash either filter.
Filters will absorb water if washed, causing food contamination and possible equipment damage.
Fig. 5 Filter Installation
OPERATION
Fig. 4 Operating Controls
CAUTION!
Personal Injury
Hazard
Disconnect power from hood and conveyor warmer before servicing filters.
IMPORTANT:
DO NOT store anything on top of the hood.
DO NOT block the exhaust opening.
IMPORTANT:
Both the high efficiency and charcoal filters must be in place at all times during operation.
7