the unit is in proper operating condition (refer to the drawing below).

¥Use No. 10 AWG (5.3mm2) copper, No. 8 AWG (8.4mm2) aluminum, No. 17 AWG (1.0mm2) copper-clad steel or bronze wire, or larger as a ground wire.

¥Secure antenna lead-in and ground wires to house with stand-off insulators spaced from 4 to 6 feet (1.22 to 1.83m) apart.

¥Mount antenna discharge unit as close as possible to where the lead-in enters the house.

¥Use jumper wire not smaller than No. 6 AWG (13.3mm2) copper, or the equivalent when a separate antenna-grounding elec- trode is used. See NEC Section 810-21 (j).

Note to CATV system installer: This reminder is provided to call the CATV system installerÕs at- tention to Article 820-40 of the NEC that provides guidelines for proper grounding and, in particu- lar, specifies that the cable ground shall be con- nected to the grounding system of the building, as close to the point of cable entry as practical.

Power Lines

Ground

ClampStandoff

Insulators

Service

EntranceMast

To External Antenna

Conductors

Terminal of Treadmill

Antenna

Lead-in Wire

Service

 

Ground

Entrance

 

Wire

Equipment

 

 

Power Service Grounding

Ground

Bonding

Electrode System (e.g.

Clamps

Interior Metal Water Pipe)

Jumper

 

Antenna

Discharge Unit

Ground Wire

Ground

Clamps

Optional Antenna Grounding Electrode Driven 8

Feet (2.44m) Into The Earth (If Required By Local

Codes). See NEC Section 810Ð21 (f).