RMM Rack Mount Modem; User's Guide

 

*

&D2

Normal DTR operations

 

 

&D3

Resets on receipt of DTR

&Fn

Loads a read-only (non-programmable) factory configuration.

 

 

&F0

Generic Template

 

*

&F1

Hardware flow control template

 

 

&F2

Software flow control template

&Gn

Sets Guard Tone

 

*

&G0

No guard tone (U.S.A. and Canada).

 

 

&G1

550 Hz guard tone (some European countries); requires B0 setting.

 

 

&G2

1800 Hz guard tone (U.K.); requires B0 setting.

&Hn

Sets Transmit Data (TD) flow control.

 

 

&H0

Flow control disabled.

 

*

&H1

Hardware flow control, Clear to Send (CTS).

 

 

&H2

Software flow control, XON/XOFF.

 

 

&H3

Hardware and Software flow control.

&In

Sets Receive Data (RD) software flow control (see also &Rn).

 

*

&I0

Software flow control disabled.

 

 

&I1

XON/XOFF signals to your modem and remote system.

 

 

&I2

XON/XOFF signals to your modem only.

&Kn

Enables/disables data compression.

 

 

&K0

Data compression disabled

 

*

&K1

Auto enable/disable

 

 

&K2

Data compression enabled

 

 

&K3

MNP5 compression disabled

&Mn

Sets Error Control (ARQ for connection at 1200 bps and higher.

 

 

&M0

Normal mode, error control disabled

 

 

&M1

Reserved

 

 

&M2

Reserved

 

 

&M3

Reserved

 

*

&M4

Normal/ARQ

file:///C/WEBPAGE/guides/rmm/rmm_manl.htm (11 of 21) [2/7/2000 10:55:43 AM]

Page 11
Image 11
Western Telematic RMM-288 Normal DTR operations, Resets on receipt of DTR, Generic Template, Sets Guard Tone, Reserved