westinghouse 17

TECHNICAL DATA

Dimensions

Electrical connection

Water supply pressure

Capacity

Width

Height

Depth

Voltage Overall power Fuse Frequency

min.

max.

Place settings

596 mm

850 mm

620 mm

220-240 V

2200 W

10 A

50 Hz

50 kPa (7 psi)

800 kPa (116 psi)

13

INSTALLATION

FITTING UNDER A KITCHEN COUNTER

Warning! Make sure that the mains plug is disconnected from the mains socket during installation.

Put the appliance adjacent to a water tap and to a water drain.

The plinth of a freestanding appliance is not adjustable.

Do not remove the worktop of the appli- ance if you want to use it as a freestanding unit.

Remove the worktop of the appliance to in- stall it under a kitchen counter (820 mm).

If a repair is necessary, the appliance must be easily accessible for the engineer. Make sure that the dimensions of the re- cess agree with the dimensions in the pic- ture.

REMOVING THE WORKTOP

1. Remove the rear screws (1).

2.Pull the worktop behind the appliance

(2).

3.Lift the worktop and move it from the front slots (3).

4.Level the appliance using the adjusta- ble feet.

5.Install the appliance under the kitchen counter. Be careful not to bend or squash the water hoses and the mains cable.

ADJUSTING THE LEVEL OF THE APPLIANCE

A correct adjustment of the level of the ap- pliance allows the door to close and seal correctly.

Page 17
Image 17
Westinghouse WSF6602 user manual Technical Data, Installation, Fitting Under a Kitchen Counter, Removing the Worktop