Oxymitter 4000

Instruction Manual

IB-106-340 Rev. 3.0 December 2003

INSTALLATION FOR METAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WALL STACK OR DUCT

 

INSTALLATION FOR MASONRY

CONSTRUCTION

 

WALL STACK CONSTRUCTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.50 [13]

 

 

 

 

 

 

 

 

0.50 [13]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MTG HOLES SHOWN ROTATED 45o OUT OF TRUE POSITION

WELD OR BOLT ADAPTER PLATE TO METAL WALL OF STACK OR DUCT. JOINT MUST BE AIRTIGHT.

 

BOLT ADAPTER

 

PLATE TO OUTSIDE

 

WALL SURFACE

3.75 [95]

 

FIELD WELD

 

PIPE TO

 

 

MIN DIA HOLE

 

ADAPTER PLATE

IN WALL

 

 

 

MTG HOLES

 

SHOWN ROTATED

 

45o

OUT OF

STACK OR DUCT

TRUE POSITION

 

 

METAL WALL

 

 

 

 

JOINT MUST

 

 

BE AIRTIGHT

 

 

OUTSIDE WALL

 

 

SURFACE

4.50[114] O.D. REF

PIPE 4.00 SCHED 40 PIPE SLEEVE (NOT BY ROSEMOUNT) LENGTH BY CUSTOMER

MASONRY

STACK WALL

NOTE: ALL MASONRY STACK WORK AND JOINTS EXCEPT ADAPTER PLATE NOT FURNISHED BY ROSEMOUNT.

BOLT ADAPTER

PLATE TO OUTSIDE

WALL SURFACE

2.50 [63.5]

FIELD WELD PIPE TO ADAPTER PLATE

3.50[89]

O.D. REF

WELD OR BOLT ADAPTER PLATE TO METAL WALL OF STACK OR DUCT. JOINT MUST BE AIRTIGHT.

MIN DIA HOLE

IN WALL

STACK OR DUCT METAL WALL

JOINT MUST

BE AIRTIGHT

OUTSIDE WALL

SURFACE

NOTE: DIMENSIONS IN INCHES WITH

MILLIMETERS IN PARENTHESES.

PIPE 3.00 SCHED 40 PIPE SLEEVE (NOT BY ROSEMOUNT) LENGTH BY CUSTOMER

MASONRY

STACK WALL

35830005

Figure 2-6. Oxymitter 4000 Adapter Plate Installation

Rosemount Analytical Inc. A Division of Emerson Process Management

Installation 2-7