Oxymitter 4000

Instruction Manual

IB-106-340 Rev. 3.0 December 2003

2

A

15o

3.584

3.554

90o

ON INSIDE BREAK FOR SMOOTH ROUNDED EDGE ON

ABOTH ENDS OF CHAMFER

.45 MIN

.187

 

 

6.00

125

 

SKIN CUT FACE FOR 90o

.187

1

 

.187

B

B

VIEW A

0.75 THRU 4 PLS,

EQ SP ON 4.75 B.C.

NOTES: 1 WELD ON BOTH SIDES WITH EXPANDING CHILL BLOCK.

2BEFORE WELDING, BUTT ITEM 2 WITH ITEM 1 AS SHOWN.

16860033

VIEW B

22.5o

.745.755 DIA ON A 7.50 DIA B.C. (REF)

Figure 1-14. Abrasive Shield Assembly

NOTE

In highly abrasive applications, rotate the shield 90 degrees at normalservice intervals to present a new wear surface to the abrasive flow stream.

Rosemount Analytical Inc. A Division of Emerson Process Management

Description and Specifications 1-13