Oxymitter 4000

Instruction Manual

IB-106-340 Rev. 3.0 December 2003

Table 1-1. Product Matrix (Continued)

Cont’d Code Communications

1HART with Membrane Keypad, blind cover

2HART with Membrane Keypad, glass cover

3HART with Local Operator Interface, glass cover, English only

Code Language

1English

2German

3French

4Spanish

5Italian

Code Filtered Customer Termination

00 Specified as Part of Electronics Housing

Code Calibration Accessories

00 No Hardware

01Calibration Gas Flowmeter and Reference Air Set

02Intelligent Multiprobe Sequencer (Refer to Table 1-3)

03Single Probe Sequencer, Horizontal Orientation, Brass/Teflon, no Reference Air Set

04Single Probe Sequencer, Horizontal Orientation, Brass/Teflon, with Reference Air Set

05Single Probe Sequencer, Horizontal Orientation, Stainless Steel, no Reference Air Set

06Single Probe Sequencer, Horizontal Orientation, Stainless Steel, with Reference Air Set

07Single Probe Sequencer, Vertical Orientation, Brass/Teflon, no Reference Air Set

08Single Probe Sequencer, Vertical Orientation, Brass/Teflon, with Reference Air Set

09Single Probe Sequencer, Vertical Orientation, Stainless Steel, no Reference Air Set

10Single Probe Sequencer, Vertical Orientation, Stainless Steel, with Reference Air Set

Code Electronics to Probe Cable Length

00 No Cable

1020 ft (6 m) Cable

1140 ft (12 m) Cable

1260 ft (18 m) Cable

1380 ft (24 m) Cable

14100 ft (30 m) Cable

15150 ft (45 m) Cable

16 200 ft (61 m) Cable

 

 

 

 

 

 

 

 

Cont’d

2

2

00

09

14

Example

NOTES:

(1)Recommended usages: High velocity particulates in flue stream, installation within 11.5 ft (3.5 m) of soot blowers or heavy salt cake buildup.

Applications: Pulverized coal, recovery boilers, lime kiln. Regardless of application, abrasive shields with support brackets are recommended for 9 ft (2.74 m), 12 ft (3.66 m), 15 ft (4.57 m), and 18 ft (5.49 m) probe installations, particularly horizontal installations.

(2)Where possible, specify SPS number; otherwise, provide details of the existing mounting plate as follows:

Plate with studs

 

Bolt circle diameter, number, and arrangement of studs, stud thread, stud height above mounting plate.

Plate without studs

 

Bolt circle diameter, number, and arrangement of holes, thread, depth of stud mounting plate with accessories.

 

 

 

Table 1-2. Calibration Components

 

 

 

Part Number

 

Description

1A99119G01

 

Two disposable gas bottles — 0.4% and 8% O2, balance nitrogen — 550 liters each*

1A99119G02

 

Two flow regulators for calibration gas bottles

1A99119G03

 

Bottle rack

*Calibration gas bottles cannot be shipped via airfreight. When bottles are used with “CALIBRATION RECOMMENDED” features, the bottles should provide 2 to 3 years of calibrations in normal service.

Rosemount Analytical Inc. A Division of Emerson Process Management

Description and Specifications 1-17