Chapter 4 Maintenance, Troubleshooting & Hardware Replacement

Initiating a Rebuild

Page 4 - 27

Drive Error

Code During

Rebuild

If a drive other than the drive being rebuilt encounters an error during the rebuild operation, the error code shown below appears, with the “X” position displaying the number of the affected drive:

If a drive being rebuilt encounters an error during the rebuild operation, the error code shown above appears without the “X” drive identifier displayed.

Note This type of error is most often some type of media error.

Code in this message is read as follows:

Code

Meaning

Hardware Error (Sense Key)

￿￿Write Fault (Additional Sense Code)

;Drive Not Ready (Additional Sense Code Qualifier) Number of Failed Drive (Field Replacement Unit number)

Table 8: Error Code Meanings

The failed drive should be replaced immediately.

If the previous message is ignored, the failed drive not replaced, and a Reset started, a second message is displayed at the completion of the Reset. This error message should be ignored.

6500 Disk Array User’s Guide

21020690 B

Page 81
Image 81
Ciprico 6500 manual Drive Error Code During Rebuild, Error Code Meanings