Chapter 3 Display/Operation Panel

Page 3 - 24

LOG PAGES

 

 

2)) 21

ENABLE LOG

This item lets you enable or disable the logging function by choosing or

 

 

. The factory default setting is 21. If you cycle power, the (1$%/(/2*

 

 

item will come up in the condition it was in when you turned off the array.

RESET LOG

This command sets all log counters back to zero and sets functions to their

 

 

default conditions. When you invoke this command, all entries for drive errors

 

 

and drive failures will be erased. The default setting is 12. To implement this

 

 

command, use the left arrow key to select <(6, then press SELECT. After a

 

 

reset, this parameter reverts to 12.

SET THRESHOLDS

This item allows you to view and set thresholds for the number of errors at which the array will automatically shut down a drive. There are separate thresholds for recovered errors and medium errors, but each of these thresholds applies to all nine drives. Factory defaults for both recovered and medium errors are zero, which indicates that the shutdown-on-threshold feature is disabled.

SET THRESHOLDS / RECOVERD

Gives access to view and set the threshold for triggering of automatic shutdowns because of recovered errors.

RECOVERED / wwwww ERRS

To set the threshold for recovered errors, press the down arrow. This causes the cursor to flash over the least significant digit of the 5-digit threshold (maximum value = 65,535). To increment the threshold setting, press the right arrow key; to decrement it, press the left arrow key. Press the down arrow again to move to the next digit. When the desired threshold is set, press SELECT.

SET THRESHOLDS / MEDIUM

Gives access to view and set the threshold for triggering of automatic shutdowns because of non-recoverable medium errors.

RECOVERED / vvvvv ERRS

To set the threshold for medium errors, press the down arrow. This causes the cursor to flash over the least significant digit of the 5-digit threshold (maximum value = 65,535). To increment the threshold setting, press the right arrow key; to decrement it, press the left arrow key. Press the down arrow again to move to the next digit. When the desired threshold is set, press SELECT.

21020690 B

6500 Disk Array User’s Guide

Page 54
Image 54
Ciprico 6500 manual Enable LOG, Reset LOG, SET Thresholds, Recovered / wwwww Errs, Recovered / vvvvv Errs