Power Supply Removal

6.Remove four screws that attach the power supply to the rear of the enclosure (see the figure below).

7.Unfasten the plastic retaining straps holding the drive power cables in place.

8.Lift the power supply out of the array enclosure.

Figure 22 Power Supply Removal—Mechanical Disconnection

Replacement Reverse the steps above.

Caution Verify that the Power Voltage Selection Switch setting on the replacement power supply matches the input power source (115 or 230 VAC). The switch is located between the two power cord connectors on the rear panel of the power supply.