21020690 B 6500 Disk Array User’s Guide
Chapter 3 Display/Operation Panel
Page 3 - 18 REBUILD
REBUILD From , use the left/right arrow keys to select the following
functions (see “Menu Structure (3 of 5—Array Info & Rebuild)” on
page 3-8). Use the display/operation panel rebuild options listed below as
described in Chapter 4 of this guide.
Caution If a disk in the array fails, replace the drive and perform a rebuild
as soon as possible. A rebuild can be performed without taking the
array off-line. See Chapter 4 for drive replacement and rebuild
instructions.

REBUILD

DATA

Your selection for the parameter determines whether or not
the data from the failed drive will be reconstructed o n the new replac ement disk
drive. means the data will be rebuilt; means the data will not be rebuilt.
Caution should always be selected for a data rebuild. Rebuilding
with this selection may result in data corruption and/or inter-
drive parity errors.
REBUILD% This menu selection allows you to select the percentage of processing time the
array will dedicate to the rebuilding process: , or . The lower
the percentage, the longer the rebuild will take. The default setting is .
START This selection must be set to before you press SELECT to rebuild a drive.