Chapter 4 Maintenance, Troubleshooting & Hardware Replacement |
|
Disabling a Failed Disk Drive | Page 4 - 23 |
Disabling a
Failed Disk
Drive
This procedure allows you to disable one drive in the array. The array stops operations on the selected drive and allows it to be physically removed.
Note The array prevents any drive from being disabled if another drive in the array is currently failed or disabled.
The procedure in the following example disables Drive .
1.Press the down arrow on the display/operation panel, then press the right or left arrows until the )81&7,216(/(&7'5,9(6menu is displayed.
2.Press the down arrow.
3. Press the right or left arrows until the ',6$%/( | menu is |
displayed. |
|
4.Press the down arrow.
5.Press the right or left arrows until the desired drive number (e.g., 5) is displayed.
6.Press SELECT. The selected drive is disabled.
6500 Disk Array User’s Guide | 21020690 B |