Electrical requirements
Electrical Shock Hazard Electrically ground dishwasher.
Connect grounding wire to green grounding nut in terminal box.
Do Not ground to a gas supply pipe.
Do Not connect dishwasher to electrical supply until appliance is permanently grounded.
Do Not have a fuse in the neutral or grounding circuit.
Failure to follow these
instructions can result in death or electrical shock.
Check with a qualified electrician if you are not sure dishwasher is properly grounded.
It is the customer’s responsibility:
To contact a qualified electrician.
To assure that the electrical installation is adequate and in conformance with all national and all local codes and ordinances.
A |
|
| |||
15ampere. | fused | electrical | supply |
| |
is required. | fuse | or |
| ||
circuit breaker is recommended. | It | ||||
is recommended | that | a separate |
| ||
circuit serving only this dishwasher |
| ||||
be provided. |
|
|
|
|
|
Grounding instructions
Dlshwasher must be connected to a grounded metal, permanent wlrlng system, or an
to the
terminal or lead on the dlshwasher.
grounding method
For your personal safety, this appliance must be grounded. This appliance is equipped with a power supply cord having a
wall receptacle, grounded in
accordance with all national and all local codes and ordinances. If a mating wall receptacle is not available, it is the personal responsibility and obligation of the customer to have a properly grounded,
The receptacle should be installed on the rear or side wall of the cabinet next to the dishwasher opening.
&prong, |
| |
wall receptacle, | m |
supply cord
IF POWERCORD CANNOT BE
USED...
When local codes Do Not permit use of a power supply cord with an undercounter dishwasher, the power supply cord must be removed and dishwasher wired directly. To direct wire this product, order kit #4317979. Electrical connections must be contained within the terminal box and meet all national and all local codes
and ordinances.
IF THE POWER SUPPLY CORD IS REMOVED, THE DISHWASHER MUST BE CONNECTED WITH COPPER WIRE ONLY.
Page 4