Power supply cord method:
NOTE: The bag containing three aluminum terminal lugs is not used when connecting the range using a power supply cord.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use new 40 amp power supply cord.
Plug into grounded outlet.
Failure to follow these instructions can result in death, fire, or electrical shock.
5.Use either
6.Complete electrical connection according to your type electrical supply
Four-wire electrical connection:
ground link
Figure1
10.Connect the neutral wire (center wire) to the center terminal screw on the terminal block. See Figure 2.
11.Connect the other two wires (lines 1 and 2) to the outer screws on the terminal block. See Figure 2.
12.Securely tighten nuts with 3/8" nut driver for proper electrical connection.
13.Tighten the strain relief screws.
14.Replace the terminal block cover.
15.Plug power supply cord into grounded electrical outlet.
Three-wire electrical connection:
center terminal block screw
WARNING - Improper connection of the
neutral wire (center wire)
center terminal block screw
ground link
ground link
line 1
neutral (center wire)
line 2
installed by a qualified electrician.
This range is manufactured with the neutral terminal connected to the cabinet. Use a
line 1
green ground wire
line 2
U.L. listed strain relief and 40 amp range power supply cord
Figure 3
Use this method only if local codes permit connecting
opening for conduit connector
remove knockout |
for 40 amp |
power cord |
and U.L. listed |
strain relief |
1.Disconnect power.
2.Remove the knockout for the 40 amp power supply cord.
3.Assemble a
4.Insert the power supply cord through the strain relief, allowing enough slack to easily attach the wiring to the terminal block.
Figure 2
Use this method for new installations, mobile homes, recreational vehicles and whenever
7.Remove the
8.Connect the green ground wire from power supply cord to the range using the
9.Use 3/8" nut driver and remove the outside nuts on the terminal block screws. Do not loosen the factory- tightened nuts behind the outside nuts.
supply cord.
7.Use 3/8" nut driver and remove the outside nuts on the terminal block screws. Do not loosen the factory- tightened nuts behind the outside nuts.
8.Connect the neutral wire (center wire) to the center terminal screw on the terminal block. See Figure 3.
9.Connect the other two wires (lines 1 and 2) to outer terminal screws on the terminal block. See Figure 3.
10.Securely tighten nuts with 3/8" nut driver for proper electrical connection.
11.Tighten the strain relief screws.
12.Replace the terminal block cover.
13.Plug power supply cord into grounded electrical outlet.
6