PROBLEM*Note: The skills and tools necessary for the safe repair of this spa require the services
of qualified service personnel. Contact your Jacuzzi Whirlpool Bath Authorized
Service Agent or Dealer.
17REMEDYPROBABLE CAUSE
7. No water flow from jets. A. Power turned off.
B. Selector switch in OFF.
C. House circuit breaker tripped; no
power to system.
D. Spa circuit protector tripped.
E. High temperature safety switch
tripped.
F. GFCI tripped.
G. Faulty pump or motor.
H. Motor(s) not connected.
I. Jet (or jets) closed.
A. Turn on power at service panel.
B. Select other function.
C. Reset circuit breaker.
D. Reset circuit protector.
E. Reset button on heater after water has
cooled; see *Note if switch continues to
trip.
F. Reset GFCI
G. *
H. Check motor plug connection on System
Control Module.
I. Open jet.
8. Noisy pump and motor. A. Clogged strainer(s).
B. Leakage of air into suction line.
C. Vibrating parts attached to motor
or support brackets
D. Low water level.
E. Damaged or worn motor bearings.
F. Impeller rubbing inside case.
G. Debris inside pump.
A. Clean strainer(s).
B. Locate and repair leaks.
C. Lighten fasteners.
D. Add water to normal water level.
E. *
F. *
G. *
9. Water leakage at pump shaft(rotating connection betweenpump and motor).
A. Worn or damaged pump seal. A. *
10. Motor will not start. A. Power off.
B. OFF mode selected.
C. House circuit breaker tripped or in
OFF position.
D. Spa circuit protectors tripped.
E. GFCI tripped.
F. Improper or defective wiring.
G. High temperature safety switch
tripped.
A. Turn on power at service panel.
B. Select FILTER, HTR/FLTR, or JETS
mode.
C. Reset circuit breaker.
D. Reset circuit protectors.
E. Reset GFCI.
F. *
G. Reset button on heater after water has
cooled; see *Note if switch continues to
trip.
6. Low water flow from jets.(Continued)
E. Suction or discharge line partially
plugged.
F. Pump running at subnormal
speed.
G. Worn or damaged pump seal.
H. Subnormal voltage.
E. *
F. *
G. *
H. Call an electrician or your power
company.
TROUBLESHOOTING GUIDE