3
Important: Read complete instructions before beginning installation.
Positioning Your Spa
Because your Razza Plus spa is portable, you can locate it just about anywhere you wish--on a deck,patio, or even
indoors. Just be sure to position it above ground in an area with good drainage and on a level, continuous surface
which can support the weight of the spa when filled with water and people; this weight is approximately 4017 lbs. You
must also provide access to the spa's equipment for service and general maintenance.
Electrical Requirements
Your Razza Plus, requires a 230 VAC 50 AMP 4-wire
grounded type electrical service having copper conduc-
tors and must be in a separate circuit having no other
appliance connected in that circuit. If you do not have
this kind of circuit, a qualified electrician should be called
in to install the necessary wiring. Inadequately sized
wiring may cause a voltage drop which might cause the
unit to malfunction and bring about permanent damage
to the spa's electrical system. We recommend that the
wire be sized for a 3% maximum voltage drop. (See
NEC.) Each "leg"of the incoming power to neutral must
be 105 VAC minimum at the spa when all the spa
equipment is running.The circuit must also have a ground
wire in order to take advantage of the designed-in safety
features of the spa. A bond wire must also be used.
Bond according to procedure described on the next
page.
Caution: Without proper grounding and bonding, a
system malfunction may cause fatal shock.
INSTALLATION
24"
26"
EQUIPMENT
DOOR
MINIMUM SERVICE ACCESS