Receptacle wiring

See the chart on page 8 for minimum gauge for receptacle wiring. Use copper wire only. It is the responsibility of the consumer to provide proper and adequate receptacle wiring, installed by a qualified electrician. Observe the National Electrical Code and all local governing codes and ordinances.

Electrical requirements

See the chart on page 8 for the voftage and amperes neces- sary for this appliance. Use a time-delay fuse or time-delay circuit breaker. It is required that a separate circuit, serving only this appliance, be provided.

Electrical connection

Electrical ground is required on this appliance.

Grounding method

For your personal safety, this appliance must be grounded. This air conditioner is equipped with a power supply cord containing a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong grounding-type wall receptacle, grounded in accordance with the National Electrical Code (ANSVNFPA 70-latest edition) and all local codes and ordinances. If a mating wall receptacle is not available, it is the responsibility of the consumer to have a proper wall receptacle installed by a qualified electrician.

ENCHUFE

REQUERIMIENTOS

AlAMBRE

 

 

 

DE COBRE

3

l

230 voltios (207 mfn.-253 max.) 0

Calibre 12

 

l

2301206 voltios (197,6 mfn.-253

 

 

 

max.)

 

 

l

O-16 amperes

 

l Disyuntor o fusible de acci6n retardada da 20 amp.

4 l 230 voltios (207 mfn.-253 m&.) 0 Calibre 10

l2W206 voltios (197,6 mfn.-253 m&J

lO-24 amperes

lDisyuntor o fusible de acci6n retardada de 30 amp.

Alambrado del tomacorriente

Ver en la tabla de la pagina 8 el calibre minim0 para el alambrado del tomacorriente. Usar alambre de cobre solamente. Es la responsabilidad del consumidor proveer alambrado del tomacorriente adecuado y apropiado, instalado por un electricista calificado. Cumplir el CXdigo National de Electricidad y todos 10s codigos y reglamentos locales vigentes.

Requerimientos ektricos

Ver en la tabla de la pagina 8 el voltaje y amperes necesarios para este artefacto. Usar un fusible de accidn retardada o disyuntor de action retardada. Se requiere que se provea un circuit0 separado para ser usado por este artefacto solamente.

Conexihn ektrica

Este artefacto debe ser puesto a tierra.

Metodo recomendado para la puesta a tierra

Para su seguridad personal este artefacto debe ser puesto a tierra. El acondicionador de aire esta equipado con un cable electrico provisto de un enchufe de puesta a tierra de tres clavijas. Para reducir a un minimo el riesgo de choque, el cable debe ser enchufado en un tomacorriente mural de tres clavijas, puesto a tierra de acuerdo con la ultima edition del Codigo National de Electricidad (ANSIMFPA 70) y todos 10s codigos y reglamentos locales. Si no se dispone de un tomacorriente mural adecuado, es la responsabilidad del consumidor hater instalar un tomacorriente mural adecuado por un electricista calificado.

10

Page 10
Image 10
Whirlpool ACM184XA0 manual Receptacle wiring, Electrical requirements, Electrical connection, Alambrado del tomacorriente

ACM184XA0 specifications

The Whirlpool ACM184XA0 is a sophisticated kitchen appliance designed to enhance cooking efficiency and versatility. Built with modern technology and a sleek design, this appliance stands out for its innovative features.

At the core of the ACM184XA0 is a high-performance induction cooking system that offers rapid cooking times and precise temperature control. Induction cooking heats up cookware directly through electromagnetic energy, ensuring that heat is generated only when suitable cookware is placed on the surface. This significantly reduces cooking time, making it a perfect option for busy households.

One of the notable features of the Whirlpool ACM184XA0 is its intuitive touch control panel, which provides easy access to a range of cooking functions. Whether you're simmering sauces, frying, or boiling, the interface allows for quick adjustments to settings with a simple touch. The appliance also includes multiple cooking zones, each with varying power levels, accommodating pots and pans of different sizes.

Safety is a primary consideration in the design of the ACM184XA0. The appliance is equipped with features such as auto shut-off and pan detection, which ensures that the induction element is only activated when suitable cookware is present. This not only prevents accidents but also enhances energy efficiency, making the cooking process more environmentally friendly.

In addition to its performance features, the Whirlpool ACM184XA0 boasts a sleek, modern aesthetic that fits seamlessly into any kitchen décor. Its minimalist design, complemented by a smooth glass surface, is not only visually appealing but also simplifies cleaning.

This induction cooktop also incorporates an innovative heat control feature, allowing users to maintain a steady temperature, which is ideal for melting chocolate or preparing delicate sauces. Furthermore, the appliance's rapid heat-up function ensures that cooking is not only efficient but also enjoyable.

With its combination of advanced technology, user-friendly controls, and stylish design, the Whirlpool ACM184XA0 is ideal for both novice cooks and seasoned chefs. It embodies the perfect blend of functionality and aesthetics, making it a valuable addition to any modern kitchen. Whether you're whipping up a weekday dinner or hosting a weekend gathering, this induction cooktop is designed to meet all cooking needs with ease.