Whirlpool AVM 512 Power setting, ON time, Microwave And Leakage Tests, S E R V I C E

Models: 512 AVM 512 AVM

1 11
Download 11 pages 43.32 Kb
Page 5
Image 5
Power setting

S E R V I C E

 

Whirlpool Europe

AVM 512

11.11.1998 / Page 5

 

Customer Service

8538 512 62291

Doc. No: 4812 714 12457

Power setting

ON time

 

 

10(highest)

100%

 

 

9

approx 93%

 

 

8

approx 87%

 

 

7

approx 80%

 

 

6

approx 67%

 

 

5

approx 60%

 

 

4

approx 53%

 

 

3

approx 40%

 

 

2

approx 33%

 

 

1 (lowest)

approx 27%

 

 

MICROWAVE AND LEAKAGE TESTS

MICROWAVE TEST

The following is a simple test to check if the appliance is generating microwave energy. This test is not intended to be an accurate test. An accurate measurement of output power must be performed under strict control following the IEC standard. In field service, accurate measurement of output power is usually not required and necessary.

Prepare a glass beaker with a diameter of approx. 190 mm round. with a max. 3 mm wall thickness.

Fill the beaker with exact 1 liter of cold water with an temperature of 10-12 ˚C measure the temperature of the water before placing into the oven.

Start the oven for 1 min. on full power (only microwave) check the time by your writwatch after the magnetron takes full power (Ampere meter).

The unit should be heated up 2-3 times before the test starts.

Check the water temperature under stirring the water and calculate the difference to the start temperature. ˚C x 70(multiplicator)=watt

Please take under consideration that always the measured power output is 15-20% lower than the rating plate shows. 850 W = 720-680 W if the measured output is below this rate please repeat the measurement.

LEAKAGE TEST

TESTING EQUIPMENT

0.5l beaker.

Microwave tester of high quality.