Whirlpool AVM 512 service manual Problem, Points To Check, Major Component Tests, S E R V I C E

Models: 512 AVM 512 AVM

1 11
Download 11 pages 43.32 Kb
Page 7
Image 7
PROBLEM

S E R V I C E

QUICK SERVICE REFERENCES

Whirlpool Europe

AVM 512

11.11.1998 / Page 7

Customer Service

8538 512 62291

Doc. No: 4812 714 12457

 

 

 

PROBLEM

POINTS TO CHECK

 

 

Cavity lamp does not light, but

Lamp burnt.

other electrical components

Bad contact between lamp and lamp socket.

(e.g. turntable) are working.

 

 

 

Cavity lamp does not light, all

Power plug not in good connection with the socket.

other electrical components

No power supply.

also do not work.

Fuse blown.

 

Bad contact between fuse and fuse holder/clip.

 

Loose door hinge, door poorly adjusted, interlock poorly

 

adjusted; causing fuse to be blown.

 

Short circuit within electrical circuit.Lamp filament short,

 

HV transformer short, all causing fuse blown.

 

Bad contact in contacts or terminals of timer switch,

 

primary and secondary interlock switch.

 

HV diode break down.

 

 

Oven seems working, food

Defective magnetron (filament broken, filament short to

does not cook

ground etc.).

 

Ground wire of HV transformer broken.

 

Filament wire short to ground.

 

Filament wire broken.

 

Bad contact in magnetron terminals.

 

Defective control boards.

 

HV diode break down, giving a hum noise.

 

 

Oven cooks for a short while

Cooling fan jammed.

and stop.

Cooling fan motor open circuit.

 

Defective cooling fan control relay.

 

 

Turntable does not turn.

Defective turntable motor.

 

Turntable shaft deformed.

 

 

User circuit breaker activates.

High leakage in electrical components (mostly motor).

 

 

MAJOR COMPONENT TESTS

 

HV TRANSFORMER

Remove lead wire.

Measure the resistance of the winding using an ohm meter

Primary winding 3 ohm (approx.)

Secondary winding 100 ohm (approx.)

Filament winding 0 ohm (approx.)

HV CAPACITOR

Remove lead wire

Measure the resistance using an ohm meter set to R*1000

Terminal to terminal should momentary indicates several ohms but gradually increases to infinite. Terminal to case should show infinite.

Page 7
Image 7
Whirlpool AVM 512 service manual Problem, Points To Check, Major Component Tests, S E R V I C E