FOR THE PLUMBER

FOR THE PLUMBER

CONFORM TO ALL APPLICABLE CODES

INSTALLDRAINS

%” O.D. TUBE SUPPLIED

FROM

ICE MAKER PUMP PAN

WITH WHIRLPOOL

BIN

t

I

 

\

BIN DRAIN

NOTE: The Ye” dra. siphon break hole must be In the verhcal leg of white vtnyl tubing.

The storage bin drains by gravity and, therefore, the drain line must maintain gradual slope to an open drain re- ceptacle. Any rise in the drain line will cause an atr lock which will prevent the water from draining from the stor-

age bin. lnstallatron of an air vent in the drain line WIII eltmlnate the posslbtltty of an air lock forming.

CONDENSERDRAIN

INSTALLWATERSUPPLY

Water treatment may be advisable because poor quality

water can cause marginal operation or malfunctton and

Increase cleanrng frequency and marntenance costs.

Contact your local Whirlpool Commercial Ice Machrne Dealer for recommendations.

WATER COOLEO

CONDENSER

Y”. MPT

ICE MAKER

Y,“O.D.COPPER

TUBE

INLET WATER

LINE

DRAIN

TUBE

 

 

ICE MAKING HEAD Cold Water Supply l/4” o.d. soft copper tube with shut-off valve.

1.A shut-off valve should be provided in the water

supply line at a convenient location near the ice maker.

The supply line must be adequately sized to compensate for the length of the run.

Supply runs over 10 feet should be made with J/e” o.d. copper tubtng. Runs of 10 feet or less may be made with ‘,4” o.d. copper tubing.

NEEDED ONLY ON WATER COOLED MODELS CHCH8WE, CHCH8WS

1.%” galvanized pipe or copper tubing must be used to

extend the condenser outlet to an open type drain.

2.Adequate flow rate must be maintained through the condenser. Runs over 40 ft. will require using larger pipe size.

*NOTE: These drains may be connected to a disposal system if high humidity or condenser cleaning causes liquid in the sump areas.

NOTE: Always flush out water lines before connecttng to prevent foreign matter from entenng the float valve.

2.Connect supply line to l/4” o.d. copper water line at center rear of Ice making head.

3.Water IS controlled in pump reservoir by float valve. Make sure float valve opens and closes.

4.Water pressure must be 20 to 100 PSI. If the pressure exceeds 100 psi, a regulator will have to be installed. The

unit will operate in pressures below 20 PSI; however, It may produce cloudy ice

CONDENSERWATERINLET

NEEDED ONLY ON WATER COOLED MODELS CHCH8WE, CHCH8WS

1.Use a 3/8” I.P.S. independent cold water supply to the water cooled condenser inlet for proper condenser operation. Runs over 40 ft. will require using larger pipe size.