FOR THE ELECTRICIAN

FOR THE ELECTRICIAN

CONFORM TO ALL APPLICABLE CODES

It IS the personal responslbrlrty and oblrgatlon of the cuslomer to contact a qualIfted installer to assure that the

electrtcal rnstallatron IS adequate and IS In conformance

with the National ElectrIcat Code and local codes and ordrnances

NOTE: A separate circuit must be used with 20 ampere time delay fuses.

REMOVE TOP SHROUD

1.Loosen screws on lower front corners of shroud.

2.Pull complete shroud forward and lift off.

CAUTION:

Use proper care when handling

this awkward

part.

 

 

INSTALLGROUNDINGWIRE

COPPER WIRE ONLY

1. Permanently ground this Ice maker In accordance

with the National ElectrIcal Code and local codes and

ordinances GROUND MUST BE CONTINUOUS

2. Use a copper conductor of the appropriate size

from the Ice maker green grounding wrre to a grounded

connectlon In the service panel or a properly driven and

electrlcally grounded rod

3. Replace electrical junction box cover

4. Replace shroud.

Alternate (Not Recommended)

1.If the recommended grounding method IS Impossible.

permanently ground the appliance from the green ground-

ing screw to a grounded cold water plpe*usrng a separate.

green colored, insulated copper conductor of appropriate size THIS. HOWEVER IS NOT RECOMMENDED

NOTE: Do not ground to a gas supply pipe Do not con-

nect to electric power supply until applrance IS perma- nently grounded

INSTALLELECTRICALWIRING

COPPER WIRE ONLY

115-2081230 V, 3-Wire, 60 Hz, 1 Ph,

20 Amp Time Delay Fuses

Install wiring according to Local and National Electrical Codes into junction box provided at rear of cabinet. Replace electrical box cover and shroud.

PROVIDE A FUSED DISCONNECT BOX WITHIN SIGHT AND EASY REACH OF THE ICE MAKER.

Be sure power supply is within + 10% - 5% of recommended voltage when machine is in operation.

TO SERVICE

PANEL

DISCONNECT

ICE MAKER

ELECTRICAL

JUNCTION BOX

AMP TIME

LAY FUSES

:I

*Cold water pipe must have metal continuity to electrical ground and

not be interrupted by plastic, rubber or other electrically insulating connectors (including water merer or pump) without adding a copper jumper wire at these connections.