GAS CONVERSIONS
Gas conversions from Natural gas to LP gas or from LP gas to Natural gas must be done by a qualified installer.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
LP Gas Conversion
1.Turn manual shutoff valve to the closed position.
2.Unplug oven or disconnect power.
B
A
C
A. To oven
B. Shutoff valve (closed position)
C. Gas supply line
To Convert Gas Pressure Regulator
1.Locate gas pressure regulator in bottom compartment.
A B
C
G
FED
A. Gas pressure regulator
B. Gas supply line
C. Electrical disconnect
D. Serial plate
E. Manual oven valve
F. Burner rating plate
G. Manifold pressure tap
IMPORTANT: Do not remove the gas pressure regulator.
2.Unscrew the
A
B
A. Regulator pin B. Regulator cap
9