Models: ET1FHTXMQ04 ET9FHTXMT03 GC3CHAXNT00 GC3CHAXNB00 GC3CHAXNQ00 GC3CHAXNS00 GC3PHEXNT02 GC5SHEXNB00 GC3PHEXNS00 GC3PHEXNS02 GC3PHEXNQ02 GC3PHEXNB02 GC3PHEXNT03 GC5SHEXNB03 GC3PHEXNQ01 GC3PHEXNT01 GC5SHEXNQ00 GC3PHEXNQ03 GC3PHEXNB03 GC3PHEXNQ00 GC3PHEXNS03 GC3PHEXNS01 GC3PHEXNT00 GT2MHTXRS01 GT1SHTXMT04 GT2MHTXRQ01 GT2MHTXRT01 GT1SHTXMB04 GT1SHTXMQ04 GC3SHEXNQ02 GC5CHAXNQ00 GC5CHAXNB00 GC3SHEXNS02 GC3SHEXNB02 GC3SHEXNT02 GC3PHEXNB00 GC3PHEXNB01

1 32
Download 32 pages 11.31 Kb
Page 15
Image 15
Model WF-NLC120V Capacity 120 Gallons (454 Liters)

Base Grille Water Filtration System

Model WF-NLC120V Capacity 120 Gallons (454 Liters)

System tested and certified by NSF International against NSF/ANSI Standard 53 for the reduction of Lead, Mercury, Benzene, p-dichlorobenzene, Cysts, Turbidity, Asbestos, Endrin, O-Dichlorobenzene, Toxaphene, Ethyl Benzene, 1,2,4-trichlorobenzene and against NSF/ANSI Standard 42 for the reduction of Chlorine Taste and Odor and Particulate Class I.

This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in ANSI/NSF 42/53.

Substance Reduction

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum%

Average%

Aesthetic Effects

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

 

 

 

 

 

 

 

 

Chlorine Taste/Odor

50%

1.9 mg/L

2.0 mg/L ± 10%

0.12 mg/L

0.08 mg/L

>75%

>75%

Particulate Class l*

85%

5,300,000/mL

At least 10,000 particles/mL

50,000/mL**

15,725/mL

99.0%

99.7%

 

 

 

 

 

 

 

 

Contaminant

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum%

Average%

Reduction

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

 

 

 

 

 

 

 

 

Lead: @ pH 6.5

0.01mg/L

0.14 mg/L

0.15 mg/L ± 10%

0.001 mg/L

0.001 mg/L

99.29%

99.29%

Lead: @ pH 8.5

0.01mg /L

0.15 mg /L

0.15 mg /L ± 10%

0.001 mg/L

0.001 mg/L

99.32%

99.32%

 

 

 

 

 

 

 

 

Mercury: @ pH 6.5

0.002 mg/L

0.0058 mg/L

0.006 mg/L ± 10%

0.0005 mg/L

0.0003 mg/L

91.37%

94.82%

Mercury: @ pH 8.5

0.002 mg/L

0.0055 mg/L

0.006 mg /L ± 10%

0.0013 mg /L

0.0005 mg/L

76.36%

90.90%

 

 

 

 

 

 

 

 

Benzene

0.005 mg/L

0.0153 mg/L

0.015 mg/L ± 10%

0.0036 mg/L

0.0014 mg/L

76.47%

90.84%

 

 

 

 

 

 

 

 

p-dichlorobenzene

0.075 mg/L

0.215 mg/L

0.225 mg/L ± 10%

0.0037 mg/L

0.0010 mg/L

98.27%

99.52%

 

 

 

 

 

 

 

 

Asbestos

99.0%**

842 x 107

107 to 108 fibers/L††

1.6 x 107 mg/L

1.6 x 107 mg/L

99.81

99.81%

 

 

 

 

 

 

 

 

Cysts

99.95%

165,500/mL

50,000/L min.

1 mg/L

1 mg/L

99.99%

99.99%

Turbidity

0.5 NTU

11.75 NTU

11 ± 1 NTU

0.38 NTU

0.22 NTU

96.76%

98.12%

 

 

 

 

 

 

 

 

Endrin

0.002

0.0056

0.006 ± 10%

0.0007

0.0004

87.50

92.85

 

 

 

 

 

 

 

 

O-Dichlorobenzene

0.60

1.84

1.8 ± 10%

0.33

0.071

82.06

96.14

 

 

 

 

 

 

 

 

Toxaphene

0.003

0.0143

0.015 ± 10%

0.001

0.001

93.00

93.00

 

 

 

 

 

 

 

 

Ethyl Benzene

0.70

2.00

2.1 ± 10%

0.60

0.169

70.00

91.55

 

 

 

 

 

 

 

 

1,2,4- trichlorobenzene

0.07

0.232

0.21 ± 10%

0.0025

0.0007

98.92

99.69

 

 

 

 

 

 

 

 

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F (17.2°C).

It is essential that operational, maintenance, and filter

 

 

 

Application Guidelines/Water Supply Parameters

replacement requirements be carried out for the product to

perform as advertised.

 

 

 

 

 

Water Supply

City or Well

Model WF-NLC120V:Change the water filter every

Water Pressure

30 - 120 psi (207 - 827 kPa)

6 months. Use replacement cartridge NLC120V, part

Water Temperature

33° - 100°F (0.6° - 37.8°C)

#4396701. 2007 suggested retail price of $34.99 U.S.A./

Service Flow Rate

0.5 GPM (1.89 L/min.) @ 60 psi.

$45.99 Canada. Prices are subject to change without notice.

 

 

 

 

 

The product is for cold water use only.

 

 

 

Do not use with water that is microbiologically unsafe or of

 

 

 

unknown quality without adequate disinfection before or after

 

 

 

the system. Systems certified for cyst reduction may be used

 

 

 

on disinfected waters that may contain filterable cysts.

 

 

 

Refer to the front cover or “Accessories” section for the

 

 

 

 

 

 

Manufacturer’s name, address and telephone number.

 

 

 

 

 

 

Refer to the “Warranty” section for the Manufacturer’s limited

 

 

 

warranty.

 

 

 

*Class I particle size: >0.5 to <1 um

**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.

These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions. ††Fibers greater than 10 um in length

Based on the use of Cryptosporidium parvum oocysts ® NSF is a registered trademark of NSF International.

15

Page 15
Image 15
Whirlpool GC3PHEXNS01, GC3PHEXNB01 Model WF-NLC120V Capacity 120 Gallons 454 Liters, Base Grille Water Filtration System