up to 1” (2.5 cm)
adjustmenttop/back edge
damper/vent connector
pivot
VERTICAL | pivot |
vent position |
HORIZONTAL vent position
11.Rectangular vent only:
Attach damper/vent connector over knockout opening. Make sure damper pivot is nearest to top/back edge of hood. Remove tape from damper flap.
Note: For horizontal vent systems, it is recommended that the rectangular ventwork be attached to the damper/vent connector and sealed with duct tape before installing the hood.
12.Round vent only:
Note: Damper/vent connector and round vent plate can be installed up to 1" (2.5 cm) on either side of hood center if ventwork is off- center. In extreme
Make electrical connection
WARNING
Electrical Shock Hazard
Disconnect power before making electrical connections.
Connect ground wire to green ground screw in terminal box.
Failure to do so can result in death or electrical shock.
Do not turn on power until installation is complete. If not
previously done, run wiring through wall or cabinets according to electrical codes and ordinances.
protective cover
13.Stand hood up as shown. (Keep on protective cover to protect hood or cooking surface.)
green ground
screw
14.Connect the white and black wires of the power supply cable to the white and black leads in the hood with
Securely tighten the strain relief.
Using a
Follow Power Cord Kit instructions for connecting wiring.
15.Replace wiring cover.
Install the hood
WARNING
Excessive Weight Hazard
Use two or more people to move and install range hood.
Failure to do so can result in back or other injury.
1/4"
(6.4 mm)
16.Remove the 4 hood mounting screws from the parts bag and install in pilot holes. Leave screw heads away from shim strips about 1/4" (6.4 cm).
keyhole slots (4)
mounting screw
keyhole slots (4)
17. Lift range hood into final position, feeding electrical wire through wiring opening. To avoid damage, DO NOT PUSH ON FAN BLADE.
Position the range hood so that the large end of the keyhole slots are over the screws. Then push the hood toward the wall so that the screws are in the neck of the slots. Tighten mounting screws to cabinet, making sure mounting screws are in narrow neck of slots. Make sure that damper blade opens and closes freely.
18.Connect ventwork to hood. Seal joints with duct tape to make them secure and air tight.
6