4
INSTALLATION INSTRUCTIONS

Tool s and Pa rts

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.

Parts supplied:

Remove parts package from dryer drum. Check that all parts
were included.
4 leveling legs

Parts needed:

Check local codes. Check existing electrical supply and venting
and see Electrical Requirements and Venting Requirements
before purchasing parts.
Mobile home installations require metal exhaust system hardware
available for purchase from the dealer from whom you purchased
your dryer. For information on ordering, please refer to the
Assistance or Service section of this manual. You may also
contact the dealer from whom you purchased your dryer.

LocationRequirements

You will need

A location that allows for proper exhaust installation. See
Venting Requirements.
A separate 30-amp circuit.
If you are using a power supply cord, a grounded electrical
outlet located within 2 ft (61 cm) of either side of the dryer.
See Electrical Requirements.
A sturdy floor to support the total weight (dryer and load) of
200 lbs (90.7 kg). The combined weight of a companion
appliance should also be considered.
A level floor with a maximum slope of 1" (2.5 cm) under entire
dryer.
Do not operate your dryer at temperatures below 45ºF (7ºC). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes or
sleeping quarters. Contact your local building inspector.

Installation Clearances

The location must be large enough to allow the dryer door to
open fully.
Dryer Dimensions
*Most installations require a minimum 5" (12.7 cm) clearance
behind the dryer for the exhaust vent with elbow. See Venting
Requirements.

Installation spacing for recessed area or closet installation

The following spacing dimensions are recommended for this
dryer. This dryer has been tested for spacing of 0" (0cm)
clearance on the sides and rear. Recommended spacing should
be considered for the following reasons:
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door and
floor moldings.
Additional spacing should be considered on all sides of the
dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
Flat-blade screwdriver
#2 Phillips screwdriver
Adjustable wrench that
opens to 1" (2.5 cm) or
hex-head socket wrench
(for adjusting dryer feet)
Wire stripper (direct wire
installations)
Tin snips (new vent
installations)
Level
Vent cl amps
Caulking gun and
compound (for installing
new exhaust vent)
Tape measure
WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
43½"
(110.5 cm)
*29¼"
(74.3 cm)
22¼"
(56.5 cm)
29"
(73.7 cm)