3.Remove plastic cover from gas pressure regulator cap.

4.Turn gas pressure regulator cap counterclockwise with a ⁵⁄₈" (1.6 cm) combination wrench to remove.

NOTE: Do not remove the spring beneath the cap.

 

Side view before

 

 

A

 

 

 

 

 

 

NG

B

 

 

NG

 

D

E

 

 

 

 

 

LP

C

Side view after

 

LP

 

 

 

A. Plastic cover

B. Gas pressure regulator cap with solid end facing out C. Gas pressure regulator cap with hollow end facing out D. Washer

E. Gas pressure regulator cap

5. Turn over the gas pressure regulator cap and reinstall on regulator so that the hollow end faces out and the marking “LP” is facing the direction shown in the above drawing.

6. Replace plastic cover over gas pressure regulator cap.

To Convert Surface Burners (Natural Gas to LP Gas)

1.Remove burner cap.

2.Remove the burner base.

B

C

D

A

A. Igniter electrode

B. Burner cap

C. Gas tube opening

D. Burner base

3.Apply masking tape to the end of a ⁹⁄₃₂" (7 mm) nut driver to help hold the gas orifice spud in the nut driver while changing it. Press nut driver down onto the gas orifice spud and remove by turning it counterclockwise and lifting out. Set gas orifice spud aside.

A

B

D

 

C

A. Igniter electrode

B. Orifice spud

C. Orifice spud holder

D. Screws

4.Remove the orifice spuds shipped in the literature package in the oven. Gas orifice spuds are stamped with a number, marked with 1 or 2 color dots, and have a groove in the hex area. Replace the Natural gas orifice spud with the correct LP gas orifice spud.

A

A. LP groove

Refer to the following chart for correct LP gas orifice spud ratings and to spud holder card for proper placement.

LP Gas Orifice Spud Chart for Surface Burners

Burner Rating/

Color

Size

ID

Placement

Type

 

(mm)

Number

 

 

 

 

 

 

15,000 BTU/

Silver

1.05

L105

LF

Stacked*

Black/Orange

0.32

L32

 

 

 

 

 

 

14,200 BTU/

Silver

1.05

L105

LF/RF

Ultra/Stacked*

 

 

 

 

 

 

 

 

 

8,000 BTU/

Red/Orange

0.85

L85

RR/CTR

Semi

 

 

 

 

 

 

 

 

 

5,000 BTU/

Red/Blue

0.65

L65

LR

Auxi

 

 

 

 

 

 

 

 

 

1,200 BTU/

Black/Orange

0.32

L32

LF

Stacked/

 

 

 

(Simmer)

Simmer*

 

 

 

 

 

 

 

 

 

*Not in all kits/models.

NOTE: Refer to the model/serial/rating plate located on the oven frame behind the top right-hand side of the oven door for proper sizing of spuds for each burner location.

5.Place Natural gas orifice spuds in the orifice spud bag.

IMPORTANT: Keep the Natural gas orifice spuds in case of reinstallation with Natural gas.

6.Replace the burner base.

7.Replace burner cap.

8.Repeat steps 1 to 7 for the remaining burners.

To Convert Oven Bake Burner (Natural Gas to LP Gas)

1.Remove the oven racks and the oven door. See the “Oven Door” section.

2.Remove 2 screws and washers at the rear of the oven bottom.

3.Lift the rear of the oven bottom up and back until the front of the panel is away from the front frame. Remove from oven and set it aside on a covered surface.

A

B

A.Screws

B.Oven bottom

17

Page 17
Image 17
Whirlpool W10665256D To Convert Surface Burners Natural Gas to LP Gas, To Convert Oven Bake Burner Natural Gas to LP Gas