Whirlpool W10665256D To Convert Surface Burners LP Gas to Natural Gas, B C D A, Burner Rating

Models: W10665256D

1 48
Download 48 pages 20.87 Kb
Page 20
Image 20
To Convert Surface Burners (LP Gas to Natural Gas)

4.Turn gas pressure regulator cap counterclockwise with a ⁵⁄₈" (1.6 cm) combination wrench to remove.

NOTE: Do not remove the spring beneath the cap.

Side view before

A

LP

4.Gas orifice spuds are stamped with a number on the side. Replace the LP gas orifice spud with the correct Natural gas orifice spud.

XXX

A

 

B

E

LP

D

 

NG

C

Side view after

NG

 

 

 

A. Plastic cover

B. Gas pressure regulator cap with hollow end facing out C. Gas pressure regulator cap with solid end facing out D. Washer

E. Gas pressure regulator cap

5. Turn over the gas pressure regulator cap and reinstall on regulator so that the solid end faces out and the marking “NG” is facing the direction shown in the above drawing.

6. Replace plastic cover over gas pressure regulator cap.

To Convert Surface Burners (LP Gas to Natural Gas)

1.Remove burner cap.

2.Remove the burner base.

Natural Gas Orifice Spud Chart B

C

Size (mm)ID NumberTo Convert Oven Bake Burner (LP Gas to Natural Gas)Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundD

A

A. Igniter electrode

B. Burner cap

C. Gas tube opening

D. Burner base

3.Apply masking tape to the end of a ⁹⁄₃₂" (7 mm) nut driver to help hold the gas orifice spud in the nut driver while changing it. Press nut driver down onto the gas orifice spud and remove by turning it counterclockwise and lifting out. Set gas orifice spud aside.

A

B

D

 

C

A. Stamped number

Refer to the following chart for the correct Natural gas orifice spud placement.

Natural Gas Orifice Spud Chart

Burner Rating

Color

Size (mm)

ID Number

19,000

BTU (ST)

White/Gray

1.84

184

 

 

 

 

 

17,000

BTU (ST)

N/A

1.75

175

 

 

 

 

 

17,000

BTU

White/Blue

1.90

190

 

 

 

 

 

15,000

BTU

White/Green

1.80

180

 

 

 

 

9,200 BTU

White/Black

1.35

135

 

 

 

 

8,000 BTU

White/Yellow

1.25

125

 

 

 

 

5,000 BTU

White/Orange

1.00

100

 

 

 

 

1,200 BTU

Black

0.52

52

 

 

 

 

 

NOTE: Refer to the model/serial/rating plate located on the oven frame behind the top right-hand side of the oven door for proper sizing of spuds for each burner location.

5.Place LP gas orifice spuds in the orifice spud bag.

IMPORTANT: Keep the LP gas orifice spuds in case of reinstallation with LP gas.

6.Replace the burner base.

7.Replace burner cap.

8.Repeat steps 1 to 7 for the remaining burners.

To Convert Oven Bake Burner (LP Gas to Natural Gas)

1.Remove the oven racks and the oven door. See the “Oven Door” section.

2.Remove 2 screws and washers at the rear of the oven bottom.

3.Lift the rear of the oven bottom up and back until the front of the panel is away from the front frame. Remove from oven and set it aside on a covered surface.

AManual background

Manual backgroundB

A. Igniter electrode

 

B. Orifice spud

A. Screws

C. Orifice spud holder

D. Screws

B. Oven bottom

20

Page 20
Image 20