Ventilation
The necessity of dissipating heat away from the unit is critical to the unit’s performance and cannot be over- stated. As the unit operates and cools, a greater amount of heat is generated on the exhaust side of the unit. Adequate ventilation is required in order to dissipate heat away from the unit. If ventilation is inadequate, the exhaust will heat up and adversely affect the unit’s ability to cool. In some cases, it may be advisable to install a vent fan to dissipate heat within the exhaust area on the backside of the unit. However, you must have a fresh air inlet as well. If your unit requires ducting, please contact WhisperKOOL Customer Service to obtain a spe- cially designed ducting accessory kit for the unit. Using any other ducting system will void the warranty.
Ambient Temperature Factor
The cooling system has the ability to cool a efficiently of 55°F as long as the ambient temperature of the area that it is exhausting to does not exceed 110°F. Therefore, you want to exhaust the unit in a room which will not exceed 105°F. Otherwise the unit will not have the capacity to keep the wine at a desirable 55°F.
Back - Exhaust Room | Front - Wine Cellar |
Exhaust Fan
110ºF | WhisperKOOL | 55ºF | |
(side view) | |||
|
| ||
|
|
|
Air Intake | Cellar Wall |
How to Build a Wine Cellar Instructional Video
WhisperKOOL has a construction tutorial available on line at our website: www.whisperkool.com. This tutorial will walk you through the steps of constructing a properly built wine cellar and the installation of our WhisperKOOL product line.