CPSM

CCS – Cellar Pre-Chill Set Point: This parameter is set at 52°f, but can be adjusted to a set point

Mode

between 45°f - 67°f.

(Cont.)

 

 

bLL/Act – Compressor Off or On for Low (bLL) or High (Act) Temperature Alarm: These parameters

 

are set at “n”. With this parameter set at “n” the refrigeration system will continue to operate nor-

 

mally, if there is a High or Low temperature Alarm. To change this parameter, change the setting to

 

“y”, and the compressor/refrigeration system will shut off during a High or Low temperature Alarm.

 

Con/Cof – Compressor On time (Con) and Off time (Cof) with a Probe 1 failure/Alarm. These pa-

 

rameters are set at Con 40 min/Cof 10 min. In the event that there is a Probe 1 failure/Alarm, the

 

compressor/refrigeration system automatically starts a predetermined ON/OFF cycle, which is con-

 

trolled by the Con and the Cof parameters. The customer can adjust these parameters to maintain

 

the desired Bottle Probe temperature. During a Probe 1 failure/Alarm, the Bottle Probe tempera-

 

ture can be monitored by pressing the Up or Down arrow to view the High and Low Temperature

 

History.

 

Hes – Differential for Energy Reduction – This parameter is set at 4, which results in a set point of

 

52°f during the Energy Reduction mode. A decrease in this setting will decrease the set point, and

 

an increase in this feature will increase the set point.

AUX

“AUX” indicates that the condenser fan is running. Pressing the “AUX” button on the control panel

 

will turn it off.

 

 

 

 

Alarm Codes

 

 

 

 

Message

Cause

 

Outputs

“P1”

Room probe failure

 

Toggle “Con” and “COF” based on your temperature needs

“P2”

Evaporator probe failure

 

Defrost end is timed

“P3”

Condenser probe failure

 

Outputs unchanged

“HA”

Max bottle probe temp alarm

 

Outputs unchanged

“LA”

Min bottle probe temp alarm

 

Outputs unchanged

“HA2”

Condenser high temperature

 

It depends on the “Ac2” parameter

“LA2”

Condenser low temperature

 

It depends on the “bLL” parameter

“EA”

External alarm

 

Outputs unchanged

“POF”

Keypad locked

 

Hold “Up” and “Down” buttons for 3 to 5 seconds to disable,

 

 

 

“PON” should appear

Page 30

PT-EXPL 020111

Page 30
Image 30
WhisperKool PLATINUM 4000, PLATINUM 8000 owner manual Alarm Codes