3. Identify and remove appropriate knockouts.
There are knockouts located on the rear panel, right side panel and on top. Remove knockouts for the two refrigeration lines and install the two grommets supplied. Remove knockout for electrical line. Keep the refrigerant pipes capped to prevent any foreign material from entering, until ready to braze.
4. Mounting housing to wall.
The unit has six mounting holes on 16 inch wide centers. Utilize all mounting screws to secure the housing to the wall (screws not included).
6” |