too often (short cycles) or not often enough (long cycles), you may want to adjust the anticipation setting.

!CAUTION

A cooling anticipation setting of less than 10 may cause decreased com- pressor life.

To adjust anticipation, press CLOCKSET and DAYSET

at the same time. The display will show HEAT 8 (this is the factory preprogrammed heating anticipation setting). You may se- lect any anticipation setting from 4 to 40. Whenever adjusting anticipation, increase or decrease the displayed number by only one or two digits, then let the system run for a while to see if the adjustment is sufficient.

If the heat cycles are too short, press TIMEFWD

to increase the cycle time. If the heat cycles

are too long, press BACKTIME to decrease the

cycle time. To set cooling anticipation, press

CLOCKSET and DAYSET at the same time again. The

display will show COOL 14 (factory prepro-

grammed cooling anticipation). Use the TIMEFWD

and BACKTIME buttons to adjust anticipation. Press

PRGMRUN to return to your program.

LOW BATTERY INDICATOR — The word BAT will flash on the display if the 9 volt alkaline battery is low and should be re- placed.

15

Page 15
Image 15
White Rodgers 1F91-71 manual To adjust anticipation, press Clockset and Dayset