Emerson 36J22, 36J54, 36J24, 36J55 installation instructions Precautions, Parts and Accessories

Models: 36J22 36J54 36J24 36J55 36J22

1 24
Download 24 pages 48.75 Kb
Page 2
Image 2

SPECIFICATIONS

Parts and Accessories:

Natural to Regulated LP Gas Conversion Kits

F92-0659for Single Stage

F92-1008for Two-Stage

Natural to Unregulated LP Gas Conversion Kit

F92-0737

LP to Natural Gas Conversion Kits

F92-0656for Single Stage

F92-1011for Two-Stage

Note: Two single stage kits may be used for two- stage valve

PRECAUTIONS

DO NOT BEGIN INSTALLATION UNTIL YOU READ THE FOLLOWING PRECAUTIONS.

 

! WARNING

 

If you do not follow these instructions exactly, a fire or explosion

 

 

mayresult,causingpropertydamage,personalinjuryorlossoflife.

 

 

1.Failure to turn off electric or main gas supply to heating system could cause personal injury and/or property damage by shock, gas suffocation, fire, and/or explosion.

2.Do not use this control on circuits exceeding specified voltage. Higher voltage will damage the control and may cause shock or fire hazard.

3.NEVER USE FLAME OR ANY KIND OF SPARK TO CHECK FOR GAS LEAKS– COULD CAUSE FIRE AND/OR EXPLOSION.

4.Do not use a control set for natural gas with LP gas, or a control set for LP gas with natural gas. Personal injury and/or

property damage, gas suffocation, fire, and/or explosion may result.

5.Do not use a gas valve which appears to be damaged. A damaged valve may cause personal injury and/or property damage due to shock, gas suffocation, fire and/or explosion. Contact supplier to replace any valve that appears to have been damaged.

6.Do not use a gas valve that has been in direct contact with water. Water entering gas valve may result in concealed internal damage to gas valve. Personal injury and/ or property damage, gas suffocation, fire and/or explosion may result.

!WARNING

Properly install gas piping to control.

Do not remove protective inlet or outlet caps until ready to connect supply pipe to gas valve.

Use new supply pipe, properly threaded, reamed, de-burred, and cleaned.

Use backup wrench, applied only to provided wrench flats on inlet boss, when tightening the supply pipe. Do not grip bracket, solenoid or any other part of control.

Do not over-tighten pipe to control (50ft-lbs max.)

Always install sediment trap in the gas supply line to prevent contamination of gas valve. Failure to install properly can cause gas leakage resulting in injury due to fire or explosion.

!CAUTION

1.Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring can cause equipment damage, property damage, and/or personal injury.

2.This control is not intended for use in locations where it may come in direct contact with water. Suitable protection must be provided to shield the control from exposure to water (dripping, spraying, rain, etc.).

3.Clean gas piping of contaminants, cutting fluid, or other chemicals which might react harm- fully with the gas valve components before install.

2

Page 2
Image 2
White Rodgers 36J22, 36J54 Precautions, Parts and Accessories, Mayresult,causingpropertydamage,personalinjuryorlossoflife