Feature Type INT32

The feature list for type INT32 has an additional column 'Exponent' which defines the feature's native unit. This exponent value is used as a unit multiplier so that the feature value is expressed as an integer, not a decimal number.

As an example from the following table, the Genie frame rate is 60000 with an exponent of 3. Therefore the frame rate native unit is mHz. The current value shown – 60000 mHz, is actually 60.000 Hz.

Feature Name

Access

Type

Exponent

Sample Value

DeviceMaxThroughput

RO

INT32

EXP10: 0

18432000

SensorWidth

RO

INT32

EXP10: 0

640

 

 

 

 

 

SensorHeight

RO

INT32

EXP10: 0

480

FrameRate (mHz)

RW

INT32

EXP10: 3

60000

BlackLevel

RW

INT32

EXP10: 0

0

Gain

RW

INT32

EXP10: 1

0

 

 

 

 

 

ExposureTime (μS)

RW

INT32

EXP10: 6

16384

TriggerDelayToIntegration (μS)

RW

INT32

EXP10: 6

0

FramesPerTrigger

RW

INT32

EXP10: 0

1

LUTNumberEntries

RO

INT32

EXP10: 0

256

DebounceInput_1 (μS)

RW

INT32

EXP10: 6

10

 

 

 

 

 

DebounceInput_2 (μS)

RW

INT32

EXP10: 6

10

PulseDelayOutput_1 (μS)

RW

INT32

EXP10: 6

0

PulseDurationOutput_1 (μS)

RW

INT32

EXP10: 6

0

PulseDelayOutput_2 (μS)

RW

INT32

EXP10: 6

0

 

 

 

 

 

PulseDurationOutput_2 (μS)

RW

INT32

EXP10: 6

0

Width

RW

INT32

EXP10: 0

640

Height

RW

INT32

EXP10: 0

480

OffsetX

RW

INT32

EXP10: 0

0

 

 

 

 

 

OffsetY

RW

INT32

EXP10: 0

0

SaperaBufferFormat

RO

INT32

EXP10: 0

16844800

PixelSize

RO

INT32

EXP10: 0

8

InterPacketDelay (μS)

RW

INT32

EXP10: 6

0

 

 

 

 

 

PacketSize

RW

INT32

EXP10: 0

1500

HeartbeatTimeout (mS)

RW

INT32

EXP10: 3

500

MaximumPacketResend

RW

INT32

EXP10: 1

10

LUTData

RW

Buffer

 

 

FlatFieldGainBuffer

RW

Buffer

 

 

 

 

 

 

 

FlatFieldOffsetBuffer

RW

Buffer

 

 

FlatFieldGainMin

RO

INT32

EXP10: 0

(see note 1)

FlatFieldGainMax

RO

INT32

EXP10: 0

(see note 1)

FlatFieldOffsetMin

RO

INT32

EXP10: 0

(see note 1)

 

 

 

 

 

FlatFieldOffsetMax

RO

INT32

EXP10: 0

(see note 1)

FlatFieldWidth

RO

INT32

EXP10: 0

(see note 1)

FlatFieldHeight

RO

INT32

EXP10: 0

(see note 1)