Faber Input Controls and Trigger Modes for Genie Cameras in the Dalsa Range

Models: M1600 M1400 M640 M1024

1 127
Download 127 pages 55.97 Kb
Page 52
Image 52

Input Controls via Sapera LT or GenICam Applications

Sapera

Genie Sapera parameters for Trigger Modes and General Inputs:

TriggerDelayToIntegration = Delay in µs from trigger to exposure TriggerEnable = {FALSE, TRUE}

TriggerSource = {Input 1 = 0, Input 2 = 1, Software = 2} TriggerSoftware = {FALSE, TRUE} FramesPerTrigger = Frame count 1 to 64k

PolarityInput_x = {Active High = 0, Active Low = 1} DebounceInput_x = debouncing period in µs (from 1 to 255 µs)

See "Accessing Features with Sapera++ LT" on page 68.

GenICam features for Trigger Modes and General Inputs:

TriggerMode = {Off = 0, On = 1}

TriggerSelector = (not used)

TriggerSoftware = Generates a software trigger to start the acquisition in software trigger mode TriggerSource = {Line2 = 1, Software = 2}

TriggerActivation = {LevelLow = 0, LevelHigh = 1}

TriggerDelayAbs = Absolute delay to apply in us after reception of the trigger signal before starting exposure

InputLineSelector = Index to general input {input1=0, input2=1} InputLinePolarity = {Active High = 0, Active Low = 1} InputLineDebouncingPeriod = debounce period in µs (from 1 to 255 µs) InputLineValue = Read input line state {low=0, high=1}

50 Operational Reference

Genie Monochrome Series-GigE Vision Camera

Page 52
Image 52
Faber M640, M1600, M1024, M1400 user manual Input Controls via Sapera LT or GenICam Applications, TriggerSelector = not used