![](/images/new-backgrounds/1262313/26231399x1.webp)
CamExpert I/O Controls Dialog
CamExpert groups the Genie I/O Controls Parameters in one group. These parameters allow configuring the Genie inputs and outputs for type of signal and signal polarity. The screen capture below shows the CamExpert I/O parameters dialog and is followed by a descriptive overview. Detailed information on inputs and outputs follow this section.
| I/O Controls Dialog |
|
|
Parameter | Description |
Trigger | Enables or disables the Genie camera trigger. |
Trigger Source | Specifies the trigger source. Possible values are Software, Input 1, or Input 2. |
| Note that this field is only available when the Trigger parameter is True. |
Frames per Trigger | Set the number of frames acquired per trigger – max. 64k |
| (driver 1.10 limited to 1 frame). |
Input Settings | Click on Setting to open the Input Settings dialog box, which allows you to specify the trigger |
| input settings. For more information, see "General Inputs: Settings Via CamExpert" on page 49. |
Output Settings | Click on Setting to open the Output Settings dialog box, which allows you to specify the |
| trigger output settings. For more information, see "General Outputs: Settings via CamExpert" |
| on page 51. |
For more information on triggers, see "General Inputs" on page 49.
48 • Operational Reference | Genie Monochrome |