CamExpert I/O Controls Dialog

CamExpert groups the Genie I/O Controls Parameters in one group. These parameters allow configuring the Genie inputs and outputs for type of signal and signal polarity. The screen capture below shows the CamExpert I/O parameters dialog and is followed by a descriptive overview. Detailed information on inputs and outputs follow this section.

 

I/O Controls Dialog

 

 

Parameter

Description

Trigger

Enables or disables the Genie camera trigger.

Trigger Source

Specifies the trigger source. Possible values are Software, Input 1, or Input 2.

 

Note that this field is only available when the Trigger parameter is True.

Frames per Trigger

Set the number of frames acquired per trigger – max. 64k

 

(driver 1.10 limited to 1 frame).

Input Settings

Click on Setting to open the Input Settings dialog box, which allows you to specify the trigger

 

input settings. For more information, see "General Inputs: Settings Via CamExpert" on page 49.

Output Settings

Click on Setting to open the Output Settings dialog box, which allows you to specify the

 

trigger output settings. For more information, see "General Outputs: Settings via CamExpert"

 

on page 51.

For more information on triggers, see "General Inputs" on page 49.

48 Operational Reference

Genie Monochrome Series-GigE Vision Camera

Page 50
Image 50
Faber M1024, M640, M1600, M1400 user manual CamExpert I/O Controls Dialog, Parameter Description